30
31
MENU
SET
Date & Time
25-Dec-2020 04:55 PM
Remain: 1,280 GAL
Capacity: 1,500 GAL
= Initial Setup Interface =
Language
Region
Valve
Meter Ratio
Salt Vs Effiiency Setting
Calculation
= Initial Setup Interface =
Language
Region
Valve
Meter Ratio
Salt Vs Effiiency Setting
Calculation
= Initial Setup Interface =
Language
Region
Valve
Meter Ratio
Salt Vs Effiiency Setting
Calculation
= Initial Setup Interface =
Language
Region
Valve
Meter Ratio
Salt Vs Effiiency Setting
Calculation
= Language =
English
= Region =
U.S. Gallon
= Valve Setting =
Filter
Downflow
Upflow
Meter Radio
1.234
Press
To Cancel
Press
To Confirm
Setting Complete
Press
To Return
Setting Complete
Press
To Return
= Initial Setup Interface =
Language
Region
Valve
Meter Ratio
Salt Vs Effiiency Setting
Calculation
= Salt Vs Effiiency =
E: 3.0 lbs Vs 5000 Grs
S: 06.0 lbs Vs 4150 Grs
H: 12.0 lbs Vs 2500 Grs
Setting Complete
Press
To Return
= Initial Setup Interface =
Language
Region
Valve
Meter Ratio
Salt Vs Effiiency Setting
Calculation
= Auto Calculation =
ON
OFF
Press
To Cancel
Press
To Confirm
Setting Complete
Press
To Return
Setting Complete
Press
To Return
Setting Complete
Press
To Return
Dont touch the default
PRESS ‘+’ AND ‘-’ FOR 8 SECONDS
PRESS MENU KEY AND SCROLL TO ‘MAIN MENU’. THEN PRESS ‘SET’ TILL IT BEEPS. SCROLL TO
ADVANCED MENU
PRESS MENU KEY AND SCROLL TO ‘MAIN
MENU’. THEN PRESS ‘SET’ TILL IT BEEPS
VALVE SETTINGS
MODELS LANGUAGE
REGION
VALVE
METER
RATIO
SALT VS
EFFICIENCY
AUTO
CALCULATION
RESIN
VOLUME
REFILL
RATE
REGEN. MODE
BACKWASH
OVERRIDE
EMERGENCY
REGEN.
REGEN
CYCLES
BRINE /
RINSE
BACK
WASH
RINSE
REGEN TIME
SETTING
SALT MODE
SETTING
BRINE
PREFILL
SET
PREFILL Injector
Injector
Color
BLFC
Washer
DLFC
Washer
DLFC
Washer
Code
LWS1.0 ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
1.0CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#0000
Black 0.2 GPM
2.0
#2
LWS1.5 ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
1.5CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#0000
Black 0.2 GPM
2.4
1S
LWS2.0 ENGLISH US GALLONS UPFLOW
1.234 DON’T TOUCH
ON
2.0CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#00
Purple 0.2 GPM
3.5
2S
Upflow Valve Programming
Below is how the settings are set at factory:
MASTER PROGRAMMING GUIDE
MASTER PROGRAMMING
The controller will show the following
on the screen - Time, Date and number
of Days Remaining for Regeneration:
How to set Master
Programming
(Authorized Dealer Only)
Press “+”
and “-“
for 8 seconds.
Press “SET”
to select and “MENU”
to go back