26
Control Valve
Distributor
Upper Cone
(18280)
Bypass - 60010004
Model
Mineral Tank
Size
Tank #
(Black Color)
Distributor #
Valve #
Media Bed #
Softener Upflow (Single Tank)
LWS1.0
9 x 48
25010036
50010005
10010044
95601
LWS1.5
10 x 54
25010051
50010005
95606
LWS2.0
12 x 52
25010060
50010005
95609
Softener
AFTER SERVICING
1.
Reconnect drain line.
2.
Return bypass or inlet valve to normal in service position. Water pressure will automatically build in the water softener
3.
Check for leaks at all sealed areas. Check drain seal with the control in the backwash position.
4.
Plug electrical cord into outlet.
5.
Set time of day and cycle the control valve manually to assure proper function. Make sure control valve is returned to the In Service position.
Unit should always be manually regenerated after servicing. If the unit was not working prior to service then 2 manual regenerations should be
done 24 hours apart to restore the full bed capacity.
NOTE
Be sure to shut off any
bypass line.
PARTS BREAKDOWN