14
MENU
SET
System initializing
Please wait
Screen Display
When power is supplied to
the control, the screen may
display “INITIALIZING WAIT
PLEASE” while it finds the
service position.
MENU
SET
Flow Rate 3 gpm/min
18-Apr-2017 10:35AM
Remain 010000GAL
Capacity 01000 GAL
The controller will show the following on the
screen: Time, Date and Gallons Remaining for
Regeneration
Familiarize with Button Configuration:
*NOTE
All units are factory pro-
grammed for the correct size
and regeneration cycle, alter-
ation should only be done by
a factory trained technician or
after consultation with one of
our technical representatives.
STARTUP & PROGRAMMING
STEP 1. Connect the Transformer to the Valve
Plug the 12-volt transformer into a 120 VAC 60 Hz outlet.
BRINE TANK MODEL
– Water to be Added at the Time of Installation:
For LWS1.0 and LWS1.5
(18.1” x 34.7” ) - 2.5 US Gallons
For LWS2.0
(20.3 x 37.4) - 3.25 US Gallons
After filling, the water level should be approximately 1” above the grid plate.
STEP 2. Add Water to Brine Tank
Open the brine tank /cabinet salt lid and add water as per
the info below. Do not add salt to the brine tank at this
time.
STEP 3. Manually Regenerate the Valve
Please see the following instructions and diagram to properly prepare your system for use.
Important - The bypass valve should be in the bypass position before completing the next steps.
1.
If screen is locked, press MENU for 5 seconds to unlock.
2.
Press MENU and scroll down using the UP and DOWN
arrows to “Manual Regen”. Press SET.
3.
Then select “Regen Now” and press SET.
4.
The control valve will advance to “Brine Drawing”. Skip
this cycle by pressing any key for 3 seconds.
5.
The control valve will advance to “Backwashing”. At
this step, unplug the power supply and slowly open
the bypass inlet valve. Allow the tank to fill with water
until all air has been purged and there is a steady flow
at the drain. Then plug the power supply back into the
outlet.
6.
Skip the rest of the backwashing step by pressing
any key for 3 seconds. The control valve will advance to
“Rinsing”.
7.
Skip the “Rinsing” step by pressing any key for 3
seconds.
8.
The control valve will advance to “Brine Refill”. Allow
this step to complete automatically. This step cannot
be skipped.
9.
Open the bypass valve outlet to the service position
and move on to the programming, STEP 4.