DM805-AI Hardware Installation Manual
15
HWMN-DM-R2011060
8. Typical Connection
Analog 0-5V Speed Mode
The 5V output of DM805-AI is connected to the COM+. The input signal is activated when it is short circuit to the signal GND. When
the
Limit
switch is activated, the motor shaft will be free and the red indicator is on.
Accel
Decel
HiSpeed
DM805-AI
Motor
20-80VDC
Disable
-Limit
Direction
Run/Stop
0~5V
COM+
Run/Stop/Pulse
DirLimit
Speed/(-)Limit
Enable/Disable
Signal GND
+5V Output
0~5V Input
Signal GND
Signal GND
Power GND
+20-80VDC
Motor A+
Motor A-
Motor B+
Motor B-
Accel/Ramp
Decel/LoSpeed
HiSpeed