background image

User Manual

DM2282

2-Phase Digital Stepper Drive

©2019 China Leadshine Technology Co., Ltd.

Address:

15-20/F, Block B, Nanshan I Valley, No.3185, Shahe West Road, Nanshan District,

Shenzhen, Guangdong, 518055, China

Tel:

(86)755-26409254

Fax:

(86)755-26402718

Web:

www.leadshine.com

Sales:

[email protected]

Support:

[email protected]

Summary of Contents for DM2282

Page 1: ...na Leadshine Technology Co Ltd Address 15 20 F Block B Nanshan I Valley No 3185 Shahe West Road Nanshan District Shenzhen Guangdong 518055 China Tel 86 755 26409254 Fax 86 755 26402718 Web www leadshine com Sales sales leadshine com Support tech leadshine com ...

Page 2: ...ase and 4 phase motors Support PUL DIR and CW CCW modes Over voltage over current phase error protections Descriptions The DM2282 is a high voltage fully digital stepper drive developed with advanced DSP control algorithm based on the latest motion control technology It has achieved a unique level of system smoothness providing optimal torque and nulls mid range instability Its motor auto identifi...

Page 3: ...ic Signal Current 7 10 16 mA Isolation Resistance 500 MΩ Operating Environment Cooling Natural Cooling or Forced cooling Operating Environment Environment Avoid dust oil fog and corrosive gases Storage Temperature 20 65 4 149 Ambient Temperature 0 50 32 122 Humidity 40 RH 90 RH Operating Temperature Heat Sink 70 158 Max Storage Temperature 20 65 4 149 Weight 1 3Kg 2 87lbs Mechanical Specifications...

Page 4: ...A O Motor Phase A 5 A O Motor Phase A 6 B O Motor Phase B 7 B O Motor Phase B Pin Assignment Control Signal Connector Pin Name I O Description 1 PUL I Pulse Signal In single pulse pulse direction mode this input represents pulse signal each rising or falling edge active software configurable see DM drives software operational manual for the detail In double pulse mode software configurable this in...

Page 5: ...tion is activated over voltage over current low voltage phase error and over temperature This port can sink or source 20mA current at 24V In default the resistance between FAULT and FAULT is high impedance in normal operation and become low when DM2282 goes into error 8 FAULT O RS232 Communication Port The RS232 communication port is used to configure the DM2282 s peak current microstep active lev...

Page 6: ...800 ON OFF ON ON 1600 OFF OFF ON ON 3200 ON ON OFF ON 6400 OFF ON OFF ON 12800 ON OFF OFF ON 25600 OFF OFF OFF ON 1000 ON ON ON OFF 2000 OFF ON ON OFF 4000 ON OFF ON OFF 5000 OFF OFF ON OFF 8000 ON ON OFF OFF 10000 OFF ON OFF OFF 20000 ON OFF OFF OFF 25000 OFF OFF OFF OFF Auto Configuration Switch SW4 two times in two seconds will activate parameter Auto configuration for DM2282 s current loop Tha...

Page 7: ...l Signal DM2282 Drive DIR Controller VCC PUL 80 220 VAC L N A A B 270O 270O 270O PUL ENA R 0 if VCC 5V R 1K Power 0 125W if VCC 12V R 2K Power 0 125W if VCC 24V R must be connected to control signal terminal R R R PUL DIR ENABLE B DIR ENA FAULT FAULT PE FAULT Stepper Motor AC Input 150 230VAC ...