CS-D508 Closed-loop Stepper Drive User Manual
Motion Control Products Ltd. Tel.: (+44) 01202 599922
11. Accessories
If you plan to use the ProTuner software, please contact us to purchase the RS232 cable with part number CABLE-PC for
connecting the CS-D508 to a computer with Windows 7/8/10 installed. In the case of using USB to RS232 conversion,
contact us for the cable with part number USB2.0-232 which has been verified working fine.
CABLE-PC
(RS232 tuning cable)
USB2.0-232
(USB to RS232 Conversion Cable)
12. Troubleshooting
In the event that your drive doesn’t operate properly, the first step is to identify whether the problem is electrical or
mechanical in nature. The next step is to isolate the system component that is causing the problem. As part of this
process you may have to disconnect the individual components that make up your system and verify that they operate
independently. It is important to document each step in the troubleshooting process. You may need this documentation
to refer back to at a later date, and these details will greatly assist our Technical Support staff in determining the problem
should you need assistance.
Many of the problems that affect motion control systems can be traced to electrical noise, controller software errors, or
mistake in wiring.
Symptoms
Possible Problems
Solutions
Motor is not rotating
No power
Connect power supply correctly
Microstep resolution setting is wrong
Setting appropriate microstep
Fault condition exists
Check wiring and restart power
The drive is disabled
Drive restore factory setting, and keep
ENA+, ENA- input signals unconnected.
Wrong motor rotation direction
The Direction signal level is reverse
Toggling the SW5 DIP switch
The drive in fault
Red light flashes once in a 5-second
period
The motor coil may short circuit or exiting
the wrong wiring
Red light flashes twice in a 5-second
period
The power supply exceeds Max. operation
voltage
Red light flashes 7-times in a 5-second
period
If using Leadshine’s motor, refer to motor
wiring diagram in the datasheet;
If using 3
rd
motor, need to swap the wiring
of motor phase A+ and phase A-
Red light is always on after power on
The drive is burned