Introduction
Please read this manual thoroughly before attempting to assemble, install or operate your
Universal Run / Stop Switch. This will assure optimum performance and safety.
The Universal Run / Stop Switch is designed to allow the user to dynamically brake a LE-v150
turbine or LE-v150 turbine at will. This is achieved by disconnecting the power output of the turbine
from the relevant load and diverting it to a short circuit which then applies the dynamic braking
effect on the permanent magnet alternator of the turbine. This will bring the turbine to a near stop
for maintenance only.
The Universal Run / Stop Switch can be used with turbines of different manufacture as long as the
relevant turbine has the following characteristics:
3-Phase Wild AC not exceeding 500 V & 16 A
Wild DC not exceeding 150 V & 10 A
Mechanically and electrically capable of dynamic braking
Operation & Specification
The Universal Run / Stop Switch should be operated during low speeds as repeated use at high
speeds may cause damage if the turbine head (it was not designed to withstand repeated dynamic
braking operations).
The switch has two positions:
Position 1: Turbine 'Stop' position. The turbine is dynamically braked and may be seen to rotate
very slowly.
Position 2: Turbine 'Run' position. The turbine output is allowed to flow straight through the switch
to the relevant output.
Safety Precautions
Safety must always be your primary concern during the assembly, installation and operation of your
turbine and other associated equipment. Always be aware of the risks involved with mechanical
and electrical installation work. If in doubt about any issue regarding your turbine system, please
seek further assistance before proceeding.
Mechanical Safety Hazards:
Whilst installing the Universal Run / Stop Switch, ensure that the turbine is suitable restrained and
not allowed to operate during the installation.
Electrical Safety Hazards:
The LE-v150 generates rectified DC voltage and the Universal Run / Stop Switch also operates at
these voltages. Even at these low voltages there are inherent risks. Caution should always be used
when connecting the LE-v150 or other equipment to the electrical system. The LE-v150 generates
high voltage AC and the Universal Run / Stop Switch also operates at these voltages. At these high
voltages there are significant risks. Caution should always be used when connecting an LE-v150 or
other equipment to the electrical system.