7. LOUDNESS DISPLAY
42
7.4
Starting and Stopping Measurements
To start and stop measurements, follow the procedure below. When measurements are being
performed, “MEAS” is displayed in the center of the screen. When measurements are
stopped, “STOP” is displayed. When the LV 7770 is standing by, “WAIT” is displayed.
This menu appears when you press F•5 LOUDNESS SETTING and set Trigger to OFF or
Mute on the LOUDNESS SETTING tab.
Procedure
AUDIO
→
F•4 LOUDNESS SETUP
→
F•3 MEASURE: STOP / START
7.5
Selecting the Scale
To select the loudness chart display scale, follow the procedure below.
Procedure
AUDIO
→
F•4 LOUDNESS SETUP
→
F•4 MAG: OFF / ON
Settings
OFF:
The target level is displayed on the scale that you selected with DYNAMIC
RANGE on the METER SETUP menu.
ON:
The target level is displayed on a scale that has a full scale ranging from -18 to
+9 (LK/LU).
MAG = OFF
MAG = ON
Figure 7-4 Selecting the scale