background image

USER MANUAL

LL PRO WASH IP65

Leader Light s.r.o.

M.Gorkeho 33

SK-052 01 Spisska Nova Ves

Slovakia

www.leaderlight.eu

All dimensions are in milimeters

ENvIRONMENt

Do not throw away the appliance with the normal household waste at the end of its life, 

but hand it in at an official collection point for recycling. By doing this, you help to preserve 

the environment.

03 INStALLAtION

03.1 Unpacking

Unpack carefully.

This is electronic equipment and should be handled carefully.

Damaged delivered package or if are any mechanical parts broken – it must be claim 

immediately by the transport company. Photo pictures as evidence are valuable for 

future claim.

-

-

-

03.2 Physical installation

Loading capacity of bearing area has to be at least 10 times the weight of all device 

clusters (luminaries, clamps, cables, ...) (figure 2.1, 2.2).

Hairbreadth from combustible materials is 0,5m.

-

-

03.3 Connecting to AC power

to tackle all Safety Information- 01!

For protection from electric shock, the device must be grounded (earthed)!

It is not necessary to open the fixture before power supply.

Power supply is solved simple with 1m cable.

The fixture is equipped with auto-switching power supply that automatically adjusts to 

any 50-60Hz AC power source from 100-260V.

Cord plug connections:

-

-

-

-

-

-

©MMX - Leader Light – All right reserved

If you have any question please, contact [email protected]

COMPLIMENtS ON YOUR PURCHASE!

Symbol

Pin

Wire Colour

Screw (US)

L

live

brown

yellow or brass

N

neutral

blue

silver

ground (earth)

yellow/green

green

03.4 Control data connecting

Control data cable length is specified by Norm IEC929 Annex E4.

It is not necessary to open the fixture before connecting of DMX512 control signal. 

Interconnections are realized by 1m cables In/Out with XLR5pin.

Pin connections:

                            Pin 1 – ground

                            Pin 2 – signal negative

                            Pin 3 – signal positive

-

-

-

Content:
01   SAFEtY INFORMAtION

        01.1 Risk of eyes damage

        01.2 Protection from electric shock

        01.3 Fire prevention

02   PROdUCt SPECIFICAtION

        02.1 Technical Specification

        02.2 Back panel

03   INStALLAtION

        03.1 Unpacking

        03.2 Physical installation

        03.3 Connecting to AC power

        03.4 Control data connecting

        03.5 DMX channels

04   PERMANENt USE LIMItAtIONS

05   MAINtENANCE

LL35 070 LL35 090 LL35 100 LL35 120

630

230

130

107,5

LEd

INdICAtION

StAtUS

POWER (Green)

blinking – 2Hz

OK - inside fixture is everything correct

DATA (Yellow)

light off

NO DMX512 signal

DATA (Yellow)

blinking – 4Hz

OK- income correct DMX512 signal

DATA (Yellow)

fast blinking

NON correct digital signal

POWER (Green)

alternate blinking

Autotest function

DATA (Yellow)

Control LEds Indication

POWER

DATA

02.2 Back panel

1m cable 

100-260V AC

1m cable XLR5pin

In/Out DMX512

Dip options

Rotating DIP 

address 000÷511

“100“ “10“ “1“

Control LEDs

MODE ADDRESS

POWER dAtA

Top cover 

Detail A

Detail A

after unscrew the top cover

WARNING!!!

Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only 

by a qualified professional in accordance with relevant local codes.

01    SAFEtY INFORMAtION

02 PROdUCt SPECIFICAtION

02.1 Technical Specification

01.1 Risk of eyes damage

Do not look directly into LED lamps.

Do not look into light beam from a distance of less than 40 cm (16 inches)!

-

-

01.2 Protection from electric shock

Shut down power before installation or maintenance.

Luminaries and recommended AC power supply must be installed by a qualified 

professional in accordance with relevant local codes. Only acceptable source of AC power 

and frequency that complies with local building and electrical codes to use.

Do not use or do not connect the products if the power cable, power plug or fixtures are any 

way damaged, wet, or if they are overheating.

Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the 

warranty.

Before removing or installing any cover or part of appliance disconnect it from AC power.

Appliance always connect to earth (eltech.).

-

-

-

-

-

-

01.3 Fire prevention

Follow all safety consideration.

Thermostatic switches or fuses never to bypass.

Device never shield. Around the axis of the fitting (180°) must be maintained space for coo

-

ling. Minimum distance from the surrounding objects must be 100mm (4 in.) (figure 1.1).

LEDs never direct cover with filters or other materials.

Allowing max. ambient temperature is 40°C (104°F).

Luminaries never use without mounting brackets.The housing never install directly to the 

surface.

-

-

-

-

-

-

Edition: A - 2010

Lamp type:

22/66 x RGBAW P4 

*

 / 22/66 x AW P4 

*

Lifetime:

Long 50 000 hrs 70% degradation

Optic:

Standard: 25°, on request: 10°, 40°, EL and AS

Control data Input:

DMX 512 In/Out with 1m cable with XLR5pin

Input power:

max. 34W/102W

Power connection:

100-260V AC 50-60Hz In 1m cable

Net weight:

3kg/5,5kg

IP:

IP65

Ambient temp. (ta):

max. +40°C

Cooling:

Conventional

Materials and finish:

Housing: powder-painted anodized aluminium in black 

(other colours on request)

Installation:

Surface mounting

*

 P4:      R-Red,     G-Green,     B-Blue,     A-Amber,     W-White (6300°K)

WARNING!!!

Non-minimum distance and/or  non-use 

the original brackets is at your own risk!

!

!

Following items are included:

- LL PRO WASH IP65 with 1m power cable, 2x1m control cable with XLR5pin

1 pc.

- User manual

1 pc.

Additional items needed:

- Controller compatible with DMX 

1 pc.

- Mounting accessories as necessary
Surface mounting:

- Screws and washers M12 or M8

Reviews: