USER MANUAL
LL PRO WASH IP65
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
All dimensions are in milimeters
ENvIRONMENt
Do not throw away the appliance with the normal household waste at the end of its life,
but hand it in at an official collection point for recycling. By doing this, you help to preserve
the environment.
03 INStALLAtION
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company. Photo pictures as evidence are valuable for
future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device
clusters (luminaries, clamps, cables, ...) (figure 2.1, 2.2).
Hairbreadth from combustible materials is 0,5m.
-
-
03.3 Connecting to AC power
to tackle all Safety Information- 01!
For protection from electric shock, the device must be grounded (earthed)!
It is not necessary to open the fixture before power supply.
Power supply is solved simple with 1m cable.
The fixture is equipped with auto-switching power supply that automatically adjusts to
any 50-60Hz AC power source from 100-260V.
Cord plug connections:
-
-
-
-
-
-
©MMX - Leader Light – All right reserved
If you have any question please, contact [email protected]
COMPLIMENtS ON YOUR PURCHASE!
Symbol
Pin
Wire Colour
Screw (US)
L
live
brown
yellow or brass
N
neutral
blue
silver
ground (earth)
yellow/green
green
03.4 Control data connecting
Control data cable length is specified by Norm IEC929 Annex E4.
It is not necessary to open the fixture before connecting of DMX512 control signal.
Interconnections are realized by 1m cables In/Out with XLR5pin.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
Content:
01 SAFEtY INFORMAtION
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PROdUCt SPECIFICAtION
02.1 Technical Specification
02.2 Back panel
03 INStALLAtION
03.1 Unpacking
03.2 Physical installation
03.3 Connecting to AC power
03.4 Control data connecting
03.5 DMX channels
04 PERMANENt USE LIMItAtIONS
05 MAINtENANCE
LL35 070 LL35 090 LL35 100 LL35 120
630
230
130
107,5
LEd
INdICAtION
StAtUS
POWER (Green)
blinking – 2Hz
OK - inside fixture is everything correct
DATA (Yellow)
light off
NO DMX512 signal
DATA (Yellow)
blinking – 4Hz
OK- income correct DMX512 signal
DATA (Yellow)
fast blinking
NON correct digital signal
POWER (Green)
alternate blinking
Autotest function
DATA (Yellow)
Control LEds Indication
POWER
DATA
02.2 Back panel
1m cable
100-260V AC
1m cable XLR5pin
In/Out DMX512
Dip options
Rotating DIP
address 000÷511
“100“ “10“ “1“
Control LEDs
MODE ADDRESS
POWER dAtA
Top cover
Detail A
Detail A
:
after unscrew the top cover
WARNING!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only
by a qualified professional in accordance with relevant local codes.
01 SAFEtY INFORMAtION
02 PROdUCt SPECIFICAtION
02.1 Technical Specification
01.1 Risk of eyes damage
Do not look directly into LED lamps.
Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
-
01.2 Protection from electric shock
Shut down power before installation or maintenance.
Luminaries and recommended AC power supply must be installed by a qualified
professional in accordance with relevant local codes. Only acceptable source of AC power
and frequency that complies with local building and electrical codes to use.
Do not use or do not connect the products if the power cable, power plug or fixtures are any
way damaged, wet, or if they are overheating.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the
warranty.
Before removing or installing any cover or part of appliance disconnect it from AC power.
Appliance always connect to earth (eltech.).
-
-
-
-
-
-
01.3 Fire prevention
Follow all safety consideration.
Thermostatic switches or fuses never to bypass.
Device never shield. Around the axis of the fitting (180°) must be maintained space for coo
-
ling. Minimum distance from the surrounding objects must be 100mm (4 in.) (figure 1.1).
LEDs never direct cover with filters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
Luminaries never use without mounting brackets.The housing never install directly to the
surface.
-
-
-
-
-
-
Edition: A - 2010
Lamp type:
22/66 x RGBAW P4
*
/ 22/66 x AW P4
*
Lifetime:
Long 50 000 hrs 70% degradation
Optic:
Standard: 25°, on request: 10°, 40°, EL and AS
Control data Input:
DMX 512 In/Out with 1m cable with XLR5pin
Input power:
max. 34W/102W
Power connection:
100-260V AC 50-60Hz In 1m cable
Net weight:
3kg/5,5kg
IP:
IP65
Ambient temp. (ta):
max. +40°C
Cooling:
Conventional
Materials and finish:
Housing: powder-painted anodized aluminium in black
(other colours on request)
Installation:
Surface mounting
*
P4: R-Red, G-Green, B-Blue, A-Amber, W-White (6300°K)
WARNING!!!
Non-minimum distance and/or non-use
the original brackets is at your own risk!
!
!
Following items are included:
- LL PRO WASH IP65 with 1m power cable, 2x1m control cable with XLR5pin
1 pc.
- User manual
1 pc.
Additional items needed:
- Controller compatible with DMX
1 pc.
- Mounting accessories as necessary
Surface mounting:
- Screws and washers M12 or M8