Activating the Standby Mode 

To activate the standby mode, perform the following steps: 

 

The device is switched off. 

1.

 

Press the on/off button until the blue and red LEDs illuminate. 

 

The standby mode is activated. 

Deactivating the Standby Mode 

To deactivate the standby mode, perform the following steps: 

 

The device is switched off. 

1.

 

Press the on/off button until the blue and red LEDs flash. 

 

The standby mode is deactivated. 

Battery Charging 

The battery is charged automatically as soon as a supply voltage 
(185 V – 265 V) is applied to the AC input. 

 

 

The battery is also charged when the device is switched off. 

 

The charging takes place with reduced charging current when 
the supply voltage (AC) is between 110 V and 185 V. 

Mains Priority Circuit 

The mains priority circuit is activated automatically when a supply voltage 
(AC) is applied to the AC input. 

If a supply voltage is applied to the AC input, the consumers are supplied 
with power by the 230-V mains and batteries are charged by the charger. 

 

 

Summary of Contents for Clayton Power G3 Combi 1012-50

Page 1: ...horshammer 6 DE 24866 Busdorf User Manual Version 2 0 Issue date 12 02 2019 G3 Combi from 1012 50 1024 30 1312 80 1512 80 1524 40 2012 100 2324 50 Lightweight and compact sine wave inverter and batter...

Page 2: ...nd Error Descriptions 17 12 Maintenance 18 13 Mount Neutrik Plug 18 14 Disposal 19 15 EU Declaration of Conformity 19 1 About this Manual Read this manual carefully and keep it in a safe place This ma...

Page 3: ...s the result of an instruction 2 General Safety This manual supports the safe handling of the device Use the device solely in accordance with its intended use The G3 Combi with a lightweight and compa...

Page 4: ...sources When handling open batteries wear acid proof clothing 3 Technical Specifications 12 V Devices Model 1012 50 1312 80 1512 80 2012 100 Output power Continuous power 1 000 W 1 300 W 1 500 W 2 000...

Page 5: ...connections LxWxH 334 x 198 2 x 116 mm 412 x 198 2 x 116 mm Weight 6 kg 7 5 kg Battery Battery type Lead acid wet gel AGM and lithium Charging characteristic IU1U2 Temperature sensor NTC optional Char...

Page 6: ...ting temperature 50 C Min operating temperature 20 C Switch off temperature 80 C Output voltage AC Nominal voltage 230 V Voltage tolerance 10 5 Frequency 50 Hz Voltage waveform Sine Max distortion THD...

Page 7: ...Current reduction at 80 C 50 Charging voltage default setting Main charging 28 8 V Trickle charging 27 V Supply voltage AC Max input voltage 265 V Minimum voltage for main charging 185 V Minimum volta...

Page 8: ...ser Manual About the Combi Page 7 of 22 5 About the Combi Details No Description 1 On off button 2 Potentiometer charging current limitation in 3 Charger LED green 4 Inverter LED blue 5 Battery LED re...

Page 9: ...ates when remote switch on D Not assigned Details No Description 6 AC input Neutrik model blue 7 Connection positive terminal of the battery 8 Connection negative terminal of the battery 9 Data connec...

Page 10: ...iption 1 Temp X1 Temperature sensor 2 Ground Ground consumer fused 3 Temp X1 Temperature sensor 4 Sync_In Out Not assigned 5 Data Single wire communication Clayton 6 Remote Connection for connecting a...

Page 11: ...device is mounted 8 Installation Determining the Cable Cross section of the Input Lead DC The following table shows the required cable cross sections in relation to the respective cable length Select...

Page 12: ...h perform the following steps 1 Connect an external on off switch to the positive terminal of the battery DC voltage min 10 V max 30 V Notice Secure the on off switch with max 1 A with 0 75 mm2 2 Conn...

Page 13: ...llowing steps 1 Press the on off button for 0 5 s Blue LED goes out Device switches off The device is switched off 10 Functions Standby Mode If the AC voltage is not required continuously a standby mo...

Page 14: ...LEDs flash The standby mode is deactivated Battery Charging The battery is charged automatically as soon as a supply voltage 185 V 265 V is applied to the AC input The battery is also charged when th...

Page 15: ...Process Battery charging takes place with a 3 stage IU1U2 characteristic curve for gentle and optimum charging of the batteries The characteristic curves can be adapted by LEAB to the batteries to be...

Page 16: ...aintain the battery charge and counteract self discharge In this phase additionally connected consumers are supplied via the charger without placing strain on the battery Load Reduction The charger in...

Page 17: ...dapts to the battery voltage in relation to the ambient temperature The figure shows the adjustment of the charging voltage in relation to the operating temperature in degrees Celsius The upper line i...

Page 18: ...D Description Steady light Charging status U2 phase Slow flashing Charging status U1 phase Fast flashing Charging status I phase Supply voltage AC too low 185 V No sine wave voltage present Supply vol...

Page 19: ...Defect in the entire bridge circuit 12 Maintenance Maintain the device at regular intervals Ensure that the cables on the battery and the G3 Combi are secure To ensure the air supply clean the ventil...

Page 20: ...ust not be disposed of with household waste Take it to a recycling point or send it to your point of sale 15 EU Declaration of Conformity The G3 Combi in models 1012 50 1024 30 1312 80 1512 80 1524 40...

Page 21: ...operating an inverter Size of the Battery Undersized batteries are often drained too deeply This reduces their efficiency and the service life of the batteries The main causes of premature ageing and...

Page 22: ...00 Ah Maintenance of the Battery Lead acid batteries must be maintained at regular intervals The battery must be maintained at least once a month in hot seasons and quarterly in cold seasons Older bat...

Page 23: ...nking or sea water Follow the manufacturer s instructions when topping up the acid level Storing the Battery Store batteries in a cool but frost free and dry environment To prevent the battery from fr...

Page 24: ...LEAB Automotive GmbH Thorshammer 6 DE 24866 Busdorf Germany Tel 49 0 4621 9 78 60 0 Fax 49 0 4621 9 78 60 260 Email anfrage leab eu Web www leab eu...