Installation instructions
Installation
Page 10 of 18
Connect the negative terminal of the battery to a common ground.
Secure the positive lead of the battery with the CF-8 fuse supplied.
Connect the negative terminal of the power pack to a common
ground.
Connect the positive terminal of the battery to the positive terminal of
the power pack.
To enable automatic charging of the battery, connect the input 3 of
the battery to the terminal 1 of the relay with a signal cable.
Connect the terminal 3 of the relay to ground.
Connect the L conductor of the AC wire of the power pack to the +A1
terminal of the relay.
Connect the N conductor of the AC wire of the power pack to the +A2
terminal of the relay.
Bridge the SW GND connection of the battery with the GND
connection of the battery with a signal line.
Connect the negative lead of the 12 V or 24 V consumers to a ground.
Connect the positive lead of the 12 V or 24 V consumers to the
positive terminal of the battery.
In single operation the battery is connected to the power pack
and the 12 V or 24 V consumers.
When installing the 12 V or 24 V consumers, pay attention to the
manufacturer information.