Switching Function of the Changeover Contact
Fig. 5: Switching
Function of the
Changeover Contact
– When the charger is switched off, pin 9 and pin 26 are
connected.
– When the charger is switched on, pin 26 and pin 18 are
connected.
Technical Data (insulation) Capacity (max. values)
Output to hous-
ing:
500 V
Max. 60 V (DC):
0.25 A
Output to ground 120 V
To install the CBL control relay, proceed as follows:
1. Solder the end of the cable to the D-sub connector.
2. Connect the wire ends to pin 26, pin 9 and pin 18.
3. Plug the D-sub connector into the connector for the
CBL control relay on the device.
ð
The CBL control relay is installed.
11 Operation
11.1 Switching On
To switch on the device, proceed as follows:
1. Connect the mains plug to a 230 V mains supply.
ð
The device is switched on.
NOTE!
After connection to the mains, the LED flashes red for 2 seconds
(device test).
NOTE!
When the battery is charging, the 'Charging' LED is lit orange.
NOTE!
When the battery is fully charged, the 'Charging complete' LED is lit
green.