Fig. 3: F1 and F2
buttons
4. Select or deselect a setting by pressing the F1 button.
5. Remove the device from the 230 V mains.
ð
The charging parameters are set and saved.
Set the following parameters for the different 'Power
Supply’ charging modes:
NOTE!
Depending on the charger, a voltage of 12 V or 24
V is permanently output as standard in the 'Power Sup-
ply' charging modes. If you require a higher voltage,
please contact LEAB directly.
Charging mode
Settings
Charging mode (default)
25, Charging mode: OFF
27, CAN mode: OFF
30: Charging mode: OFF
PDO Power Supply
25, Charging mode: OFF
27, CAN mode: ON
30: Charging mode: OFF
SDO Power Supply
25, Charging mode: ON
27, CAN mode: ON
30: Charging mode: OFF
13
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
LEAB Automotive GmbH
7 Setting the Charging Parameters