CONTROL
Smoke Output
: 0 – 99% variation
Smoke Pre–Delay
: Time in seconds before actual smoke issue (FreezeFog use)
Fan
: 0 - 99% phase control for Optional Fan control Output.
TIMER
On
: Timer for Smoke Issue or select not used
Off
: Timer for Interval of non smoke issue or select not used.
DMX
DMX
: Selects the base DMX address
Use
: Option to use the next address for Pre-Delay or not
Use
: Option to use the next address for Fan Control
SMOKE
This button is a separated function switch and will control the smoke output regardless of the
‘Selection’
position.
The ‘DMX’ and ‘MANUAL’ buttons switch between these two modes of operation. It may be necessary to hold
either of these buttons down a short while, so that the software loop is given time to react, particularly if in the
DMX mode with no actual signal.
The ‘Store/DMX’ led reacts and blinks if DMX is selected when there is no signal. It will remain solid if a DMX
signal is present.
How to set the DMX mode of operation as standard from ‘power on’
Disconnect all DMX signal leads from the G300MkIII. Select DMX mode and the status LED should be blinking.
Now press the DMX and STORE buttons and wait for the Status LED to blink quickly several times. Check by
turning the machine Off then On again. DMX mode should be set. To revert to Manual use, just press the Manual
button.