background image

Arpa F & PC 150 LED  User’s Manual – 1.0 

 

 

Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy 

Tel. +39 0376 771 777 – fax +39 0376 772 140 – emai

[email protected]

 – web www.ldr.it 

 

 

5.       VOLTAGE 

 

Before operating this unit please refer to the product label mounted at the back of the luminaire to check you are 

operating with the correct voltage.  
The ARPA LED  

can be operated between 90V and 260V

 and the electronic PSU inside the fixture will automatically switch 

to the available voltage.

 

 

 

6.     FREQUENCY  

 

Frequency on this product is automatically selected by the electronic PSU (50/60Hz). 

 

        

7.      CONTROL FUNCTIONS AND OPERATION 
OPERATION

:  LCD display for DMX address, system setup and status details. 

POWER

:  power LED status indicator  , red color.   ON= power  

DMX

:  DMX LED status indicator, green color.  LED OFF = DMX OFF and manual control activated , LED ON  =  DMX MODE 

activated with no DMX signal,  FLASHING   LED = receiving DMX    

MENU

: rotary switch selector to select and modify the operational modes.  Turn  left or right to navigate through the 

menu and press to select or to confirm 

DMX IN

:  input DMX signal (pin1=0 , pin2= DATA- , pin3=DATA+ ). 

DMX OUT : 

 Loop through DMX signal output 

POWER IN:  

Mains power input  

POWER OUT

: Mains power output 

FUSE

:   5x20 6.3A HPC FAST 

 

 

       

8.      MENU 

 

There are thirteen different operation menus for the setting of the ARPA LED  control functions.  The rotary selector is 

used to adjust the settings and to navigate through the menu structure.  Turn left or right to select the menu and push 

to access or to confirm the selected data or functions.   
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 01151000

Page 1: ...PC150 W LED 3200K Arpa PC150 C LED 5600K istruzioni per l uso operating instructions Bedienungsanleitung instrucciones de manejo mode d emploi gebruiksaanwijzing Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Page 2: ...tion 5 8 4 DMX frequency control 5 8 5 Lost DMX signal 5 8 6 Strobe 6 8 7 Strobe speed 6 8 8 Dimming curve 6 8 9 Cut off dimming response 7 8 10 Dimming behaviour 7 8 11 LED frequency adjustment 7 8 12 LCD retro illumination 7 8 13 Software version and LED temperature 7 8 14 PRO BASIC 7 8 15 Reset 8 MAINTENANCE 9 Fuse replacement 8 10 Cleaning and maintenance 8 11 Spare parts 8 12 Warranty 8 SUMMA...

Page 3: ...operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The limitation extends to damages for personal injury property damage loss of operations loss of profits loss of product or loss of time whether incurred in by the customer the customer s employees or a third party Apart from the instructions given on this manual all relevant safety and h...

Page 4: ...m FLOOD The beam distribution peak flat is fixed Beam shaping a 4 leaf barndoor A20100306 can be fitted on the front of the Arpa to control and shape the beam 4 WIRING Before being connected to the mains power this unit may need to be wired with a suitable plug if not already installed Make sure the plug you are using is rated for the proper power load and it conforms to the relevant EU UL electri...

Page 5: ...setup and status details POWER power LED status indicator red color ON power DMX DMX LED status indicator green color LED OFF DMX OFF and manual control activated LED ON DMX MODE activated with no DMX signal FLASHING LED receiving DMX MENU rotary switch selector to select and modify the operational modes Turn left or right to navigate through the menu and press to select or to confirm DMX IN input...

Page 6: ... to 16 bits with 2 DMX channels Factory setting 8 Bit 8 4 DMX FREQUENCY CONTROL DMXCfg If turned ON it allows to remotely control the LED Frequency or the strobe speed through a dedicated DMX channel Factory setting OFF 8 5 LOST DMX SIGNAL DMXMem In case of signal failure this function allows to store in memory the last DMX value Factory setting ON Three options are available 1 M Manual XX 1 M DMX...

Page 7: ...rves is available LED HAL to reproduce halogen behavior square and linear Factory setting LED HAL 5 DMXMem OFF 80 DIM THE LED TO 80 OF ITS MAXIMUM POWER 5 DMXMem OFF 0 DIM THE LED TO 0 6 Strobe DISABLE 6 Strobe DISABLE 6 Strobe ENABLE TURN TO SELECT MANUAL OR DMX AND PRESS TO CONFIRM PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR 7 SetStr OPEN W...

Page 8: ...ast setting Factory setting AutoOFF 8 13 SOFTWARE VERSION AND TEMPERATURE CONTROL V 1 0 This function allows to visualize the software version and the LED temperature in C 8 14 PRO or BASIC CONTROL ProBasic The PRO BASIC control is a special function which allows to limit the access to the control menu To activate this function turn OFF and ON the Cetra and press the rotary switch at power on Sele...

Page 9: ...ct a regular maintenance service should be carried out Please make sure the product is cold and disconnected from power supply when doing this clean all reflective parts such as reflector mirror and lens opening the product if necessary check the lamp and the lenses and replace any visibly damaged component clean air ducts and fans in order to allow a proper ventilation activity on the product che...

Page 10: ...ontrolled through DMX DMXCfg function enable OPEN ON SPEED xx select value from 01 slowest to 10 fastest CLOSED OFF OPEN 8 Curves select the dimming curve LED HAL SQUARE LINEAR LED HAL 9 CutOff replicate the halogen lamp dimming behaviour at cut off FAST NOT ACTIVE SLOW ACTIVE SLOW 10 Smooth dimmere response OFF Immediate response SLOW 300ms FAST 150ms Smooth 11 Freq set the LED frequency This men...

Page 11: ...en declaran bajo su responsabilidad que los productos aquì listados I sono conformi alle seguenti norme ed ai requisiti delle seguenti direttive CEE GB conform to the following standards and to the requirements of following EEC directives D den nachfolgend aufgeführten Normen und EEC Vorschriften entsprechen F sont conformes aux normes et prescriptions CEE ci aprés E cumplen de hecho con las sigui...

Page 12: ... Faulty product Defekte s Produkt Produit défectueux Producto defectuoso Descrizione del problema Problem found Beschreibung des Defekts Description du défaut Descripciòn del problema ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ ______...

Page 13: ...ble for delivering the appliance to an appropriate collection facility at the end of its useful lifespan Appropriate separate collection to permit recycling treatment and environmentally compatible disposal helps prevent negative impact on the environment and human health and promotes recycling of the materials making up the product For more information on available collection facilities contact y...

Page 14: ...Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Reviews: