Arpa F & PC 150 LED User’s Manual – 1.0
Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy
Tel. +39 0376 771 777 – fax +39 0376 772 140 – email
– web www.ldr.it
4
5. VOLTAGE
Before operating this unit please refer to the product label mounted at the back of the luminaire to check you are
operating with the correct voltage.
The ARPA LED
can be operated between 90V and 260V
and the electronic PSU inside the fixture will automatically switch
to the available voltage.
6. FREQUENCY
Frequency on this product is automatically selected by the electronic PSU (50/60Hz).
7. CONTROL FUNCTIONS AND OPERATION
OPERATION
: LCD display for DMX address, system setup and status details.
POWER
: power LED status indicator , red color. ON= power
DMX
: DMX LED status indicator, green color. LED OFF = DMX OFF and manual control activated , LED ON = DMX MODE
activated with no DMX signal, FLASHING LED = receiving DMX
MENU
: rotary switch selector to select and modify the operational modes. Turn left or right to navigate through the
menu and press to select or to confirm
DMX IN
: input DMX signal (pin1=0 , pin2= DATA- , pin3=DATA+ ).
DMX OUT :
Loop through DMX signal output
POWER IN:
Mains power input
POWER OUT
: Mains power output
FUSE
: 5x20 6.3A HPC FAST
8. MENU
There are thirteen different operation menus for the setting of the ARPA LED control functions. The rotary selector is
used to adjust the settings and to navigate through the menu structure. Turn left or right to select the menu and push
to access or to confirm the selected data or functions.