Installation
1
Mounting
Actuators
The touchless actuator may be mounted in
conventional plastic electrical gang boxes
. Ensure that the unit sensor does
not come in contact with any metal components within the gang box to avoid shorting out the unit.
Do not place the sensor in the door’s opening range, where the sensor may see door movement. Do not place moving
objects in front of the sensor.
Use the weather resistant gasket as a protective barrier against the elements.
For electrical box installation, refer to the mounting box instructions that come with the product.
L
NOTE: Actuators are recommended for interior use only!
1a If using an in-wall box ensure the box is plumb and square, and flush with the wall surface.
If using a surface box, ensure it is secure & plumb.
1b Using the dip switch located on the end of the unit, set the operating mode. (See Section 3: Setup).
1c Attach the unit to the enclosure using the two #6-32 screws provided.
1d Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.
L
Note: Do not overtighten!
Receivers
The receiver is designed to mount under the cover or in the header, depending on the model. Screw holes are located at
each end of the receiver case, or the included hook and loop fastener may also be used to hold it securely.
2
Wiring
CAUTION
Do not apply power to the unit until all secondary wiring is complete, and dip-
switches have been set.
Actuators
The actuator is powered from 2 AA batteries (supplied). The battery holder has been pre-installed. Insert the batteries into
the battery holder. Please be careful that the polarity of the batteries is correct.
TRANSMITTER
Request To
Exit Input
Power In -
Power In +
Diagram 1