background image

Model 8310-2210

Installation Instructions

Description

Actuator

Available faceplates:
Single gang: 2-3/4” x 4-1/2” stainless steel, fits on single gang electrical boxes.

Receiver

•  3 Modes of Operation:

•  Delayed  (1 - 15 Seconds)

•  No Delay  (1 – 30 Seconds)

•  Latching

•  Adjustable Range:  3’ - 300’

•  40 Transmitter capacity: delayed, non-delayed or both 

•  Form ‘C’ Relay Output

•  12/24V AC/DC operation

•  915 MHz

•  Dimensions:  2-5/8” x 1-1/2” x 

13/16”

Technical specifications

Actuators

Descriptions

8310-2210 Series

Number of IR sensors

1

Batteries (supplied)

“AA” alkaline batteries

Estimated battery life

2 years (based on 100 operations/day)

Standard operating range

1” - 12” (25.4mm - 304mm) 

Factory set to 6” (152mm)

Operating mode

Momentary

Inputs

“Request to Exit” (to trigger the relay remotely or from the other side of the door)

Wireless output

Built-in 915 Mhz. spread spectrum wireless transmitter

Receivers

Descriptions

8310-2210 Series

Operating voltage

12/24V AC/DC

Current Draw

23 mA nominal @ 24V AC/DC
43 mA maximum @ 24V AC/DC

Response time

30 - 200 ms

Memory delay & No delay

40 transmitters total

LEDs

Indicate: relay status; learn mode; erase mode; and potentiometer position

Output

1 x SPDT relay contact

Rating

3 amps @ 30 VDC

Operating time

1 - 30 seconds

Delay time

1 - 15 seconds

Frequency

915 Mhz

Mounting

2 #4 screws at 3” centers or hook and loop fastener (supplied)

Enclosure

Clear plastic case

Dimension

2-5/8” x 1-1/2” x 13/16”

8310-2210 Series Touchless Actuator/

Transmitter Battery Powered Contactless Switch

Summary of Contents for 8310-2210 Series

Page 1: ...4mm 304mm Factory set to 6 152mm Operating mode Momentary Inputs Request to Exit to trigger the relay remotely or from the other side of the door Wireless output Built in 915 Mhz spread spectrum wirel...

Page 2: ...it is secure plumb 1b Using the dip switch located on the end of the unit set the operating mode See Section 3 Setup 1c Attach the unit to the enclosure using the two 6 32 screws provided 1d Attach th...

Page 3: ...p Switch Bank 1 Dip Switch Bank 2 8310 2200 Series Description Function SW1 SW2 Description 1 LED Enable Green LED flashes while the output is activated Momentary OFF OFF The output operates once and...

Page 4: ...de Set DIP1 to ON Press PB1 using a small blunt object such as a small blade screwdriver or similar Within 10 seconds press the switch connected to 8310 2210 actuator The Green LED Array flashes to co...

Page 5: ...LED is solid again L Note Toggle mode disables delayed mode Transmitter programmed as delayed mode will work as toggle mode transmitter Signal strength adjustment For the most reliable consistent ope...

Page 6: ...outside of door header Unable to program Stuck actuation or faulty transmitter Disconnect each push plate until LED goes out Verify DIP 1 is on LED activation signal ON Faulty actuator transmitter Ch...

Page 7: ...3 4 5 12 24V AC DC NO COM NC 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 4630 4640 Series Electric Auto Equalizer ACTUATOR TRANSMITTER RECEIVER 9100 Series Benchmark 24 VDC 24 VDC SAFETY SEN...

Reviews: