Defender Press Brake Guarding System Operation Manual
LS-CS-M-069
Page 29
Original Language Version: 1.04
Released:
01/04/2020
When pressed and released, the
MUTE RESET
button will flash three times while the mute
point is cleared. During this time the message
Mute point resetting
–
PRESS FOOT PEDAL TO
CANCEL
is displayed. After the reset is complete, the screen again appears as in
prompting the operator to
SET MUTE POINT
–
PRESS FOOT PEDAL.
MENU
MODE
SELECT
TOOL
SETUP
MUTE
RESET
INFO
ACTION
NORMAL MODE
Ready to bend
0000
A
STATUS
STD
Figure 6-8: Mute Set, Ready to Bend
6.5
Selecting Tray/Box Modes
To change the optical protection mode the Defender panel must be in the Mode Select
screen. From the Main screen press the
MODE SELECT
button, and the screen will change to
the Mode Select screen.
When changing modes the tools must be open with the laser above the mute point and clear
of any obstructions. Also, the system should be in Normal mode (the default start-up mode).
If these conditions are not met, the Status window will display the message
Open tools to
enable button function
.
FIELD
MUTED
GUARD
MODE
MUTE
STOP
BACK
GAUGE
ACTION
NORMAL MODE
Ready to bend
0000
STATUS
A
STD
Figure 6-9: Mode Select Screen
Note:
Do not press the foot pedal while the
MUTE RESET
label is flashing. If the foot pedal
is pressed, the mute reset operation will be cancelled.