Sentinel Press Brake Guarding System Operation Manual
LS-CS-M-066
Page 27
Original Language Version: 1.06
Released:
03/07/2019
M ENU
M OD E
SELECT
TOOL
SETU P
SET
INFO
ACTI ON
PRESS FOOT PEDAL
SET MUTE POINT
0000
A
B
STATUS
Figure 6-4: Set Mute Point Prompt Screen
Figure 6-5: Material Placement on the Die
Press the foot pedal and the tools will close until sensor B (the bottom sensor) is obstructed
by the sample material. The Sensor window will show sensor B as obstructed, and the
SET
button will change colour to green, which indicates that the mute point can now be set, as
seen in
Note:
During mute point set-up the Sentinel Press Brake Guarding System uses only the front
and middle detection zones of the sensors to detect the material.
Laser Field
Material Sample