Preset Filter Cycles
The first preset filter cycle begins 6 minutes after the spa is energized. The second
preset filter cycle begins 12 hours later. Filter duration is programmable for 2, 4, 6, or 8
hours or for continuous filtration (indicated by ). The default filter time is 24 hours. To
program, press “Temp,” then “Pump 1.” Press “Temp” to adjust. Press “Pump 1” to exit
programming. The circulation pump and the ozone generator run 24 hours. In hot
environments, the circulation pump may turn off for 30 minute periods, except during
filter cycles. At the beginning of each filter cycle all other equipment will run briefly to