R-BBU  BATTERY  BACK-UP  UNIT  

INSTRUCTION  MANUAL 

 

IMPORTANT  INSTALLATION  INSTRUCTIONS 

 

WARNING

 

– 

To reduce the risk of severe injury or death to persons.

 

 

1. 

READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 

 

2.  Make sure the available power supply to be connected to the device is of the same voltage, frequency 

and phase as indicated on the nameplate of the device. 

 

3.  Read and understand the wiring diagram of the device and any other equipment to be connected to the 

device. 

 

4.  Always disconnect power whenever installing or servicing the device. 

 

5.  All wiring must be permanent and comply with National Electrical Code (NEC) and local code 

requirements. 

 

6. 

For “Indoor Dry” location use only. 

 

        Disconnect power at the fuse box before proceeding with any wiring. 

 

                                  

 

 

   SPECIFICATIONS 

 
 

ELECTRICAL 

   Input Power :    

 
100~240 VAC , 50 / 60 Hz  ,  1.7A Max. 
 

Battery  : 

 

Output Power : 

24 VDC ,  5AH 

 

24 VDC ,  1A Max. 

 

 

NOTES: 

1.  This battery back-up device is for providing 24VDC power only, and is intended to be used with a 

release device. 

 
2.  Device must be connected to power source for at least 8 hours to fully charge batteries. 

 

 

 

WARNING

 

Summary of Contents for R-BBU

Page 1: ...BATTERY BACK UP UNIT R BBU V2 INSTRUCTION MANUAL ...

Page 2: ...ment to be connected to the device 4 Always disconnect power whenever installing or servicing the device 5 All wiring must be permanent and comply with National Electrical Code NEC and local code requirements 6 For Indoor Dry location use only Disconnect power at the fuse box before proceeding with any wiring SPECIFICATIONS ELECTRICAL Input Power 100 240 VAC 50 60 Hz 1 7A Max Battery Output Power ...

Page 3: ...icated by an audible or visible warning WARNING SOUND CONDITION SOUND PATTERN AC Fail B B B B B B No Battery B B B B B B B B Battery Low B B B Battery Fail B B B B B B B B Charging Fail B B Disconnect power supply to the device before servicing Inspect and service whenever a malfunction of the device or equipment connected to it is observed or suspected Before servicing always disconnect power sup...

Page 4: ...U S GEAR 11 2019 R BBU DIMENSIONS U S Gear 12 10 3 ...

Page 5: ...AC 24VDC Output VOICE WARNING MODULE R BBU Connections FS EP 18 19 Input MAINBOARD Alarm Dry Contact TERMINAL PCB CN2 11 12 24VDC Output VOICE WARNING MODULE TERMINAL PCB CN2 35 36 TERMINAL PCB CN2 10 10A FTS 18 19 Input MAINBOARD Alarm Dry Contact TERMINAL PCB CN2 11 12 24VDC Output VOICE WARNING MODULE TERMINAL PCB CN2 10 10A 4 ...

Page 6: ...ndby Hrs AR D up to 10 hours AR D2 up to 12 hours FS EP 30 50 FTS up to 7 hours FS EP 70 150 FTS up to 3 3 hours 10 Optional extra battery pack to extend standby Hrs 24 VDC 5AH X 2 sets battery X 4 AR D up to 30 hours AR D2 up to 36 hours FS EP 30 50 FTS up to 21 hours FS EP 70 150 FTS up to 9 9 hours 11 Net Weight lbs kgs 7 7lbs 3 5kgs not including battery 12 Gross Weight lbs kgs 17 6lbs 8kgs in...

Page 7: ...U S GEAR 11 2019 6 ...

Page 8: ...U S GEAR 11 2019 FS EP Board with YELLOW 18 19 Socket Pin FTS N M MK Boards with GREEN 18 19 Connector FS EP FTS X XK Boards with GREEN 18 19 Connector 7 ...

Page 9: ...U S GEAR 11 2019 R BBU FS EP FTS X XK MAINBOARD PCB FS EP FTS X XK Boards with GREEN 18 19 Connector R BBU FS EP MAINBOARD PCB FS EP Board with YELLOW 18 19 Socket Pin 8 ...

Page 10: ...U S GEAR 11 2019 R BBU FTS N M MK MAINBOARD PCBS 9 ...

Page 11: ...U S GEAR 11 2019 R BBU AR D AR D2 10 ...

Reviews: