1.  Structure supporting device must be adequate for weight of device. 

 

2.  Attach panel to wall using suitable fasteners for mounting conditions, such as  

  expansion or sleeve anchors into concrete 

  sleeve anchors into masonry 

  self-tapping screws into steel framing  

  lag screws into wood framing 

On drywall construction, it may be necessary to bridge across studs with a suitable support system. 

 

MAINTENANCE  INSTRUCTIONS 

 

1. Replace batteries with the same type every two years or less. [24VDC, 5AH X 1 set (battery X 2)] 

 

2. Check and replace batteries if output voltage is below 19 volts. (Low battery may be indicated by an 

audible or visible warning). 
 

WARNING SOUND 

CONDITION 

SOUND PATTERN 

AC Fail 

B----B.B., B----B.B. 

No Battery 

B----B.B.B., B----B.B.B. 

Battery Low 

B.     ,B.     ,B. 

Battery Fail 

B.B.B.B.B.B.B.B. 

Charging Fail 

B------,B------ 

 

    

                         

Disconnect power supply to the device before servicing. 

 

 

  Inspect and service whenever a malfunction of the device or equipment connected to it is observed 

or suspected. 

  Before servicing, always disconnect power supply to the device. 

  Replace fuses only with those of the same type and rating. 

  All replacement parts must be compatible with those originally provided. Consult manufacturer for 

replacement parts. 

 

 

Do not place hands or tools in the device when the power is connected or when 
testing the device or equipment connected to it. Always disconnect power before 
servicing or adjusting the device or other equipment connected to it.  

 

WARNING

 

 

WARNING

 

Summary of Contents for R-BBU

Page 1: ...BATTERY BACK UP UNIT R BBU V2 INSTRUCTION MANUAL ...

Page 2: ...ment to be connected to the device 4 Always disconnect power whenever installing or servicing the device 5 All wiring must be permanent and comply with National Electrical Code NEC and local code requirements 6 For Indoor Dry location use only Disconnect power at the fuse box before proceeding with any wiring SPECIFICATIONS ELECTRICAL Input Power 100 240 VAC 50 60 Hz 1 7A Max Battery Output Power ...

Page 3: ...icated by an audible or visible warning WARNING SOUND CONDITION SOUND PATTERN AC Fail B B B B B B No Battery B B B B B B B B Battery Low B B B Battery Fail B B B B B B B B Charging Fail B B Disconnect power supply to the device before servicing Inspect and service whenever a malfunction of the device or equipment connected to it is observed or suspected Before servicing always disconnect power sup...

Page 4: ...U S GEAR 11 2019 R BBU DIMENSIONS U S Gear 12 10 3 ...

Page 5: ...AC 24VDC Output VOICE WARNING MODULE R BBU Connections FS EP 18 19 Input MAINBOARD Alarm Dry Contact TERMINAL PCB CN2 11 12 24VDC Output VOICE WARNING MODULE TERMINAL PCB CN2 35 36 TERMINAL PCB CN2 10 10A FTS 18 19 Input MAINBOARD Alarm Dry Contact TERMINAL PCB CN2 11 12 24VDC Output VOICE WARNING MODULE TERMINAL PCB CN2 10 10A 4 ...

Page 6: ...ndby Hrs AR D up to 10 hours AR D2 up to 12 hours FS EP 30 50 FTS up to 7 hours FS EP 70 150 FTS up to 3 3 hours 10 Optional extra battery pack to extend standby Hrs 24 VDC 5AH X 2 sets battery X 4 AR D up to 30 hours AR D2 up to 36 hours FS EP 30 50 FTS up to 21 hours FS EP 70 150 FTS up to 9 9 hours 11 Net Weight lbs kgs 7 7lbs 3 5kgs not including battery 12 Gross Weight lbs kgs 17 6lbs 8kgs in...

Page 7: ...U S GEAR 11 2019 6 ...

Page 8: ...U S GEAR 11 2019 FS EP Board with YELLOW 18 19 Socket Pin FTS N M MK Boards with GREEN 18 19 Connector FS EP FTS X XK Boards with GREEN 18 19 Connector 7 ...

Page 9: ...U S GEAR 11 2019 R BBU FS EP FTS X XK MAINBOARD PCB FS EP FTS X XK Boards with GREEN 18 19 Connector R BBU FS EP MAINBOARD PCB FS EP Board with YELLOW 18 19 Socket Pin 8 ...

Page 10: ...U S GEAR 11 2019 R BBU FTS N M MK MAINBOARD PCBS 9 ...

Page 11: ...U S GEAR 11 2019 R BBU AR D AR D2 10 ...

Reviews: