PBU-150-11
09/22
SPECIFICATIONS
Model
PBU-150-11
Output Power (Continuous)
1500VA
Output Voltage
120VAC
Output Waveform
Pure Sine Wave
Output Frequency
60Hz
Input Voltage
120VAC
Input Frequency
60Hz
Nominal Battery Voltage
36VDC
Batteries
12VDC, 12Ah x 3
Applicable Door Operator Models
MGH/MGRL 3311E, 5011E
MGH 7511E
SGH 5011E, 7511E, 10011E, 15011E
FS/FSML-31EP
FS-51EP, 71EP
FTS-51X
FGH/FGRL 3311E
FGH 5011E, 7511E, 10011E, 15011E
New Weight (including batteries)
60.6lbs / 27.5kgs
Notes:
1. This AC power backup unit is a 120VAC single phase power supply for motor operating during
AC power absent and is intended to be used with the models shown in the specifications.
2. This device must be connected to power source for at least 12 hours to fully charge batteries.
INSTALLATION INSTRUCTIONS
1. Structure supporting device must be adequate for weight of device.
2. Attach panel to wall using suitable fasteners for mounting conditions, such as
Expansion or sleeve anchors into concrete
Sleeve anchors into masonry
Self-tapping screws into steel framing
Lag screws into wood framing
On drywall construction, it may be necessary to bridge across studs with a suitable support system.