V_pro8 Manual
V1.0/2
21
Installation & Configuration
Frame Installation
Frame Installation
Front View
Rear View
The
pro8
can be mounted either in a 19" equipment rack or on a table top as follows:
19" Rack-Mounting
- fix the optional rack-mounting brackets to the front of the chassis. Then
attach to a standard 19" equipment rack. Please install supporting slide bars to hold the
weight of the unit.
Table Top
- the unit should be laid on a flat, horizontal surface.
Plug-in connectors are located at both the front and rear. Therefore, make sure that all
connectors are accessible.
When using 19’’ racks with doors please leave enough room for the cables!
Dimensions and Weight
Width: 480.3mm (19“)
Depth: 457.5mm (18")
Height: 1RU
Weight: 4.6kg (10 lbs and 2.26 oz)
Temperature and Cooling
The unit is fitted with six fans inside, and ventilation holes on the left and right. Proper operation is
guaranteed between temperatures of 0° C and 40° C and a maximum relative humidity of <= 90%
non-condensing.
Warning
DO NOT
obstruct the ventilation holes as to do so will prevent efficient cooling.