Problem
Motor does
not start
Abnormal
noises
Abnormal
vibrations
Poor results
Possible causes
Unit not plugged in
No electricity
Defective cable
Defective safety switch/plug
Overheat protection activated
Tine is jammed
Lubrication running out
Bolts,
nuts
or
other
components are loose.
Tines damaged or worn
Working depth too large
Working depth too small
Worn tines
Remedy
Plug in the unit
Check power supply
Check cable.Repair or replace if required
Arrange for repair
1. Working depth too large, set to a shorter
depth.
2. Tines blocked, remove the blockage.
3. Soil too hard, select correct work depth
and move forward and backward several
times while slowing down the operation
speed. Wait until the motor cools down for
about 15 minutes before further use.
Switch off. Wait till tines comes to a completes
top. Remove jammed objects.
Tiller/cultivator must be repaired. Send in to
Service Centre for repair.
Tighten all components. Arrange for repair if
noises continue.
Replace damaged or worn tines.
Set to correct working depth
Set to correct working depth.
Replace damaged or worn tines