21
A STEELFORT PRODUCT | STEELFORT.CO.NZ
spark arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Reinstall the spark arrester in the
7.
muffler and attach with the two screws.
3.9 SPEED
The speed has been pre-set during manufacturing
and should not require readjustment. Consult your
local Service Dealer and or a professional to enquire
about this.
WARNING
Unapproved adjustment will damage your engine
and/or your electrical devices. Tampering with the
factory set governor will damage your generator and
void warranty.
3.10 ADJUSTMENT
•
There are no other service and/or adjustment
needs for your generator.
•
Unapproved adjustments or tampering can
damage the generator and the electrical
devices that may be plugged into the unit
•
Contact your local service dealer for further
information.
WARNING
Tampering with the factory set governor will damage
the generator and void warranty.
V. STORAGE & TRANSPORT
STORAGE
The generating set should be started at least once
every two weeks and allowed to run for at least 20
minutes. Follow the instructions below for long term
storage (out of service for 2 months or more).
DANGER
FIRE OR EXPLOSION
Petrol is highly flammable and extremely explosive.
Empty the fuel tank and shut off the fuel valve before
storing and or transporting the generator.
1. Allow the generator to cool completely before
putting it away for storage.
2. Clean the generator according to the
instructions in the Maintenance section.
3. Drain all fuel completely from the fuel hose
and carburetor to prevent gum deposits from
forming.
4. Turn off the fuel supply at the fuel valve.
5. Change the oil.
6. Remove the spark plug and pour 15 ml of oil
into the cylinder. Crank the engine slowly to
distribute the oil and lubricate the cylinder.
7. Reattach the spark plug.
8. Store the unit in a clean, dry area out of direct
sunlight.
TRANSPORTATION
To prevent fuel spillage when transporting or during
temporary storage, the generator should be secured
upright in normal operating position, with the engine
switch OFF. The fuel valve lever should be turned
OFF.
WARNING
WHEN TRANSPORTING:
•
Do not overfill the tank.
•
Do not operate the generator while it is on or
inside any vehicle. Take the generator out off
the vehicle and use it in a well-ventilated area.
•
Avoid placing the unit in exposed direct
sunlight, especially inside vehicles. If the
generator is left in an enclosed vehicle for
many hours, high temperatures could cause
fuel to vaporise resulting in a possible
explosion.
•
Do not drive on a rough roads for extended
periods with the unit on board. If you must
transport the unit through rough roads, drain
the fuel beforehand.
Summary of Contents for PB Series
Page 7: ...7 A STEELFORT PRODUCT STEELFORT CO NZ 3 FEATURES CONTROLS...
Page 22: ...22 A STEELFORT PRODUCT STEELFORT CO NZ VI TROUBLESHOOTING...
Page 23: ...23 A STEELFORT PRODUCT STEELFORT CO NZ VII SPECIFICATIONS SINGLE PHASE...
Page 24: ...24 A STEELFORT PRODUCT STEELFORT CO NZ VII SPECIFICATIONS...
Page 26: ...26 A STEELFORT PRODUCT STEELFORT CO NZ 3 WIRING DIAGRAMS 2 3 6KW ELECTRIC START...
Page 27: ...27 A STEELFORT PRODUCT STEELFORT CO NZ 2 3 6KW RECOIL START...
Page 28: ...28 A STEELFORT PRODUCT STEELFORT CO NZ 4 8 KW ELECTRIC START...