II. Guided Programming (Optional)

In guided programming, the controller display  prompts you to

enter data for items by flashing the appropriate A. It automatically

prompts you to supply information about the current time and

date, program start time(s), valve run time(s) and watering days

for program and program B. After all items are entered 

,

 an

“OK” will be flashed five times to verify programming is complete.

If you have not entered the required data during the guided

programming session, the controller will flash the message         

and prompt you for the missing data. The purpose of guided

programming is to allow you to enter a program without this
manual.

To begin, set dial to GUlDED  PROGRAM. This will lead you
through five easy 

steps

Use the + and - buttons to increase or

decrease times. Use the 

 button to enter your selection and to

advance to the next step. After setting the time and date,

program (or B) A will flash. You will be prompted to complete

program A. If required, you may continue with program by
pressing the A/B button. After the final programming step, the

controller will flash “OK”. You will then be prompted to set-up the

other program, (or A), if desired. After all desired programming
is done, set dial to RUN position to begin automatic operation.

Hint: 

Plug in 9 volt alkaline battery t

o  allow programming at

your kitchen table

.  install controller after programming by

battery.

Guided  Programming Steps

1. 

T/ME/DAT

E - Enter the year, the month, the date and the

time. This will set the controller’s internal timing. Use + and -

buttons to increase or decrease values and the 

 button to

go to the next step.

2. 

PROGRAM A o

r B - Select either program or B. Press the

3.

4.

5.

A/B  button to select. Press 

 button to go to the next step.

START T/M

E  - Enter the program watering start time(s). Each

program can have up to two start times. (Two start times allow

watering twice a day.)

 

RUN  T/ME - Enter the length of time that each valve is

to run. You may select a few minutes for a light sprinkling, or

you may set the valve to remain open for up to four hours for
applications such as drip. (The valve is off when the run time is
set to zero minutes and the display shows “OFF”). Press + or -

buttons to increase or decrease the minutes of run time per

valve. Press 

 button to go to the next valve or to the next step.

WATER DAY

S  - Enter which days should be watering days.

You may select particular days of the week, all odd days or all

even days. Press the + button to turn days on and the - button

to turn days off. Press the 

 button to go to the next day or

to the next step.

Summary of Contents for Lawn Dial LD-4

Page 1: ......

Page 2: ...ograms are completely independent of each other giving you the freedom to include any combination of valves in each program and the ability to select different watering days and start times for each p...

Page 3: ...sired programming is done set dial to RUN position to begin automatic operation Hint Plu g in 9 volt alkaline battery t o allow programming at your kitchen table install controller after programming b...

Page 4: ...the and buttons to change the month 4 Day Press the 4 button to set the day of the month Use the and buttons to change the day of the month The day of the week e g Sunday Tuesday etc is automatically...

Page 5: ...stop one program without turning the dial to the OFF position You may need the other program to water Setting Valve Run Times Follow the steps below to program how long each valve will water 1 Set th...

Page 6: ...lected days will show at the top of the display to indicate their status as ON 1 Press the 4 button for Odd Days and once again for Even Days The A will flash under your choice 2 Press the button to s...

Page 7: ...ience landscape damage if the dial is left unintentionally in the OFF position for extended periods of time Always return the dial to RUN position if automatic operation is desired IV Manual Programmi...

Page 8: ...manual valve program Always return dial to RUN position to enable automatic operation Note You may advance through a running cycle by pressing the 4 key to skip any undesired valve s V Installation Se...

Page 9: ...AC Do not plug in transformer until after all valves have been connected 2 Connect valve l wire to screw marked 1 and the valve common wire to main common wire which feeds back to the controller Typic...

Page 10: ...r for more information l Valves 5 6 located on model LD 6 only PUMP START RELAY TO PUMP o r PUMP STARTER _ c CONTACTS MUSS ACCOMODATE PUMP S ELECTRICAL RATING PUMP POWER Connecting a Pump Start Relay...

Page 11: ...A to suit your needs without affecting the default You may change all the programs to suit your specific needs without affecting the factory default values There is no factory default for program B No...

Page 12: ...more of the following measures 0 Reorient or relocate the receiving antenna l Increase the separation between the equipment and receiver l Connect the equipment into an outlet on a circuit different...