Lawn Genie L60204 Installation And Operation Manual Download Page 5

Connect the transformer

A. Run the power cable from the transformer up through
the smaller of the two openings in the bottom of the
controller,

B. Connect one lead to each terminal screw marked 24V
Make sure terminals at the end of the cable do not touch.
C. Plug in the transformer.

A

CAUTION: Use with supplied transformer ONLY!

Connect the battery

A battery back-up system is built into your Lawn Genie
controller to maintain your programmed watering
schedule in memory in case of temporary power failure.
A. Connect a 9-volt alkaline battery (not supplied) to
the battery connector in the wiring compartment
of the controller case.
B. Place the battery in the wiring compartment by
pushing the connector end, in and under the transformer
power cable terminals.
C. Replace the wiring compartment cover,
D. Replace the battery once a year. More often if frequent
power failures occur.

A

CAUTION: Do not allow the battery connector to
touch the transformer power cable, or the terminal
wiring to the right. D0 not connect or disconnect
valve wires while any Zones are in operation,

NOTE. Check local codes to ensure that wiring
and installation meet all requirements.

In the controllers display, 

   

 represents 12PM, or

noon, and 

   

 represents 12 AM, or midnight. When

the power is first turned on, the controller always
displays a time of        (4:00 PM). Setting the current
time is easy.

Set the current time:

A. Press 
B. Press 

 and hold key down until display shows

current hour and A (AM) or P (PM).
C. Press 

and hold key down until display

shows current minute. To advance time quickly, hold
down 

 or 

 until desired time approaches.

To advance time slowly, digit by digit, press 

 or

 once for each hour or minute of advance.

NOTE: You must begin setting time within
30

 seconds 

after pressing 

 Otherwise,

you must press 

 once again.

Set the current day number

A. Press 

6. Repeatedly press 

 until the current day

number is displayed. Days are represented by the
following numbers.

Sunday = 1
Monday = 2
Tuesday = 3
Wednesday = 4
Thursday = 5
Friday = 6
Saturday = 7

C. Press 

 to return to the clock mode

Summary of Contents for L60204

Page 1: ...awn Genie Dual Program Electronic Controller Installation and Operation Guide b For Models L60204 L60206P L60208P b Please read instructions completely before attempting to install or operate controller ...

Page 2: ...her foliage all need different amounts of water You can tailor the water delivered to different parts of your yard by assigning a different run time to one or more sprinkler valves Each valve and the sprinklers it controls are called a Zone The L60204 lets you divide your yard into as many as four Zones the L60206P allows up to six and the L60208P permits a maximum of 8 Zones Programming options C...

Page 3: ...f key Rain Switch For preventing watering during wet weather or winter and de activating Zones using the Zones and Days keys Start keys For setting up to six start times per day shared between Program A and B in any combination Days keys For setting watering days for each Program Zones keys For programming run times for each Zone Display Shows current time of day Zone being watered and watering ru...

Page 4: ...ng tabs into recessed slats in back of controller housing To lock in place pull down on controller until tabs reach built in stops IMPORTANT The power transformer is protected by an electronic circuit breaker Do not connect a combination of valves requiring an inrush current of more than 1 amp at 24 VAC One valve only for regular models Two valves for P Series models Connect the valve wires to con...

Page 5: ...nsformer power cable or the terminal wiring to the right D0 not connect or disconnect valve wires while any Zones are in operation NOTE Check local codes to ensure that wiring and installation meet all requirements In the controllers display i z P represents 12PM or noon and z R represents 12 AM or midnight When the power is first turned on the controller always displays a time of I 0 0 P 4 00 PM ...

Page 6: ...start times to each Program Now You re ready to select the times of day that each Program will begin watering the Zones assigned to it Your controller lets you set as many as six start times a day shared in any combination between Programs A and B i e 2 in Program A 4 in Program B or 3 starts in each Program and so on Remember when you enter a start time for a program all Zones in that program wil...

Page 7: ...nce to display 10 5 This indicates Zone1 is set to run for 5 minutes on the days assigned to Program A B If you want Zone1 to remain in Program A press Ma until the desired run time appears Display will increase up to 99 minutes and begin counting again from one minute C To prevent Zone1 from watering in Program A press ON OR to display fli 1 D Continue pressing s and repeating Steps B and C until...

Page 8: ... z once to display I I Continue B If you do not want Program A Zones to water on Sundays programming from Step B of the specific days of press the s until II F appears the week section page 14 C Press fi to display day I Monday and set to NOTE Your controller has a preset factory 0 fl or 0 1 I by pushing the E key again program which will keep your system operating D Repeat the previous steps unti...

Page 9: ...r each Zone 1 Set Zones l 4 to water lawn areas for 15 minutes under Program A 2 Set Zone 5 and 6 to water shrubbery for 15 minutes under Program B To connect your controller to a well pump or master valve If your water doesn t come from the pipes of a standard public water supply you may be using a pump to draw directly from a well pond or similar source In these cases you ll need to make the fol...

Page 10: ...tically revert to your programmed schedule after watering has finished in manual or semi automatic mode Interrupting the watering cycle Pause Function To freeze a manual or semi automatic watering cycle at any point in the Zone s run time press s The display n will flash lSSE To resume the watering cycle press s again and the Zone s count will continue NOTE If PAUSE is activated and forgotten the ...

Page 11: ...erlapped with another start time Too many start times Clock has correct time and Zones 1 appear to be functioning properly 2 but no valves will turn on 3 One Zone won t shut off 1 electrically 2 One or more Zone are set to 0 F F The common wire is not connected Valve flow stem is screwed down too far Faulty valve Particles of dirt or debris are stuck in valve WARNING Do not link two or more contro...

Page 12: ...ther costs of removal or reinstallation of any so called defective products NO IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO FITNESS FOR A PARTICULAR PURPOSE WHERE APPLICABLE AND MERCHANTABILITY SHALL EXTEND BEYOND THE PERIOD OF THE EXPRESS WARRANTY DESCRIBED ABOVE IN NO EVENT SHALL LAWN GENIE BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES TO PROPERTY WHICH MAY ARISE FROM OR RELATE TO TH...

Page 13: ...un lime location Start limes 1 maximum total of six Program A or Program B 2 3 4 5 6 q LawnGenie 9455 Railroad Drive El Paso TX 79924 915 757 2586 800 231 5117 q Hardie Irrigation AJllml Hardle company 24 200702 REV A 1 93 ...