WARNING!
Before cleaning and servicing the machine, you must turn the machine off and disconnect battery and propane
tank
ATTENTION!
Wait until turbine impeller has completely stopped before starting servicing the machine.
The exhaust will get very hot after running the engine for just a short time
Before moving the dust collector from the working area, the machine must be cleaned.
All other equipment must be considered to be contaminated and be treated thereafter.
If possible, use a special suitable room.
Proper personnel protective equipment must be used.
After a service, all parts that are contaminated must be taken care of properly in plastic bags, according to
all regulations.
If the dust collector has to be used for other purposes, it is extremely important that the machine is
cleaned to avoid the spread of hazardous dust.
In order to ensure safe and efficient operation of the dust collector, the following procedures should be performed
periodically (depending on the frequency of operation):
Remove and inspect the filters for any signs of excessive wear or damage. Replace as necessary. (See
section on “Filter Removal”).
Ensure that the gaskets on the filters are free of excessive wear or damage. Replace as necessary.
Inspect all electrical components (switches, plugs, cables, etc.) for damage or exposed wiring. Replace as
necessary.
Ensure that all screws, bolts, and nuts are properly tightened.
Check the waste container level. Always clean and change the bag when the debris reaches a maximum of
75% of its full capacity.
Check the flexible vacuum hose and accessories for significant wear or damage. If holes are present, the dust
collector’s efficiency will be reduced, and debris will leak into the work environment. IMPORTANT: All major
repair work should be performed by Superabrasive or an authorized repair facility.
Check the turbine belt tension.
Check and clean the Propane installation.
CHECK DAILY
After operating the
V25GX
, the operator should conduct a visual inspection of the machine. Any defect should be
solved immediately. Pay attention to plugs and vacuum hoses, loose bolt or screws.
CHECK AND REPLACE AFTER THE FIRST 8 WORKING HOURS
Replace the oil in the engine after the first 8 hours work, according to the instructions of the engine manufacturer.
ALWAYS USE 30HD OR 10W30 ENGINE OIL WITH ALL OF THE FOLLOWING RATINGS: SF, SG, AND CC
CHECK AND REPLACE EVERY 50 WORKING HOURS
Change engine oil, while changing check for leakage of engine oil at the various seals. The hour meter will blink
between 48-52 hours as a reminder/"Engine Oil Capacity" is 1.5L(1.6US.qt) when oil filter is not removed ;
1.7L(1.8US.qt) when oil filter is removed.
Recommended Oil Change Intervals
Do not exceed the 50-hour oil change interval. Oil changes more frequent than 25 hours will give even longer engine
life. In any case, always use 30HD or 10W30 engine oil with all of the following ratings: SF, SG, and CC. make sure the
oil level is maintained at the "FULL" level.