APPENDIX A
ERROR CODES
All errors are displayed on line 4 of the display when the 6300 is in the Main screen. An
error must be acknowledged before any other key entries are accepted. The error may be
acknowledged either by pressing the CANCEL or the CLR key.
ERROR CODES
DESCRIPTION
1
Pressure exceeded 110 %FS on Pt output
2
Pressure exceeded 110 %FS on Ps output
3
Pt target value exceeds Qc limits
4
Pt target value exceeds Mach limit
5
Ps rate target exceeds Rate limit
6
Ps target exceeds altitude limits
7
Pt actual value exceeds Qc limit
8
Pt actual value exceeds Mach limit
9
Rate exceeds limits.
10
Unused
11
Invalid Profile point
12
Ps control-transducer error
13
Pt control-transducer error
14
Ps actual value exceeds limit
15
Internal Use only
16
Internal Use only
17
If Pt is left in Measure mode, Qc limit will soon be exceeded
18
If Pt is left in Measure mode, Mach limit will soon be exceeded
19
Loss of Actual Data