Installation
Part No. 70476501ENR7
29
1 Fire Suppression System Control Box
2 Water Solenoid Valve
3 Opening for Auxiliary Alarm Cable
Figure 3
To connect the two hoses (supplied with tumble dryer), insert
rubber washers (from literature pack) in water inlet hose
couplings. Refer to Figure 4 .
1 Lock
2 Hose Couplings
3 Y Valve
4 Inlet Hoses
5 Opening for Auxiliary Alarm Cable
Figure 4
Connect inlet hoses to water supply. Flush the lines for
approximately two minutes to remove any foreign materials
that could clog the screens in the water mixing valve. This is
especially important when installing a tumble dryer in a newly
constructed or renovated building. Then connect the hoses to the
Y-valve; connect the Y-valve to the connections at the rear of
the tumble dryer.
IMPORTANT: Thread hose couplings onto valve
connections finger tight, then turn 1/4 turn with pliers.
Do not cross thread or overtighten couplings.
IMPORTANT: Hoses and other natural rubber parts
deteriorate after extended use. Hoses may develop
cracks, blisters or material wear from the temperature
and constant high pressure they are subjected to. All
hoses should be checked on a yearly basis for any
visible signs of deterioration. Any hose showing the
signs of deterioration listed above should be replaced
immediately. All hoses should be replaced every five
years.
NOTE: Longer inlet hoses are available (as optional
equipment at extra cost) if the hoses supplied with
the tumble dryer are not long enough for installation.
Order hoses as follows:
Part No. 20617 Inlet hose 8 feet (2.44 m)
Part No. 20618 Inlet hose 10 feet (3.05 m)
Summary of Contents for GA120L