ethernet-debug=x
This command enables a set of Toast based messages suitable for the user.
The messages report the status of the Ethernet interface.
The permitted range is 0 to 3. The default is 1.
Level
Messages
Comments
0
No status messages
1
“LTM – ethernet connected”
Reported when the Ethernet state changes from
not connected to connected.
1
“LTM – ethernet not connected”
Reported when the Ethernet state changes from
connected to not connected.
2
“LTM – ethernet not connected”
Reported each pass of the LTM application if
the Ethernet interface is not connected to the
network. The message repeats every 30
seconds.
3
“LTM – ethernet remains connected”
Reported each pass of the LTM application if
the Ethernet interface is connected to the
network.
Note: Each level includes the messages of the lower levels.