- 6 -
GAS REQUIREMENTS
%
Use propane or LPG only.
%
The heater is designed for use with 11-15kg cylinder. Maximum size of cylinder suitable for the
appliance, w/ regulator attached, is
42 cm x 73 cm. Inner dimension of stand within the side panels is
42 cm x 73 cm.
%
The appliance requires approved gas hose in 60 cm length and a regulator
%
Regulator maximum inlet pressure must not exceed 690 kPa (100 PSI).
%
Regulator outlet pressure must be 28-30 mbar.
%
The hose and regulator assembly must conform to local standard codes.
%
The installation must conform to local codes, or in the absence of local codes, to the standard for the
storage and handling of liquid petroleum gases.
%
A dented, rusted or damaged gas cylinder may be hazardous and should be checked by your gas
supplier. Never use a gas cylinder with a damaged valve connection.
%
The gas cylinder must be arranged to provide for vapor withdrawal from the operating cylinder.
%
Avoid twisting the flexible tubes and hoses.
%
Never connect an unregulated gas cylinder to the heater.
%
Disconnect the gas cylinder when the heater is not use.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness
check must be performed at the installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater. The heater must be checked with a full cylinder.
1. Make sure that the appliance is switched off.
2. Make a soapy water solution of one part liquid detergent and one
part water. The soapy water solution can be applied with a spray
bottle, brush or rag to all gas connections. Soap bubbles will appear
in case of a leak.
3. Switch on the gas supply.
4. In case of a leak, switch off the gas supply. Tighten any leaking fittings, then turn the gas supply ON and
recheck. Contact your dealer or gas supplier for assistance if bubbles continue to appear.
WARNING
Never leak test while smoking.