Lava Aire Fantom User Manual Download Page 4

Cleaning and Maintenance 

 

1.  Please unplug the unit before cleaning it. 

2. Please clean the water tank every two or three weeks, and clean the flume every week. 

3. Please take out the water tank when cleaning it and pull the plastic tube out of the atomizing cup properly, then 

take out the atomizing cup and clean them. 

4. Use a dry cloth to absorb water remaining when cleaning the atomizing cup and dry it using a piece of soft cloth. 

Or use mild detergent to clean the atomizing cup if it is dirty. 

5. Please add a few drops of lubricant to the motor shaft after cleaning to extend motor life every year. 

6. Pack this appliance properly and store it in a cool dry place if you are not using it for a period of time. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequently Asked Questions

  

 

If your fan is not working properly, please check the followings (1-4 for mist function) before sending to service agent: 

 

Questions 

Answers 

Solution(s) 

1.  Why  is  there  no  mist  and  no  wind 

from fan? 

a.  Power  cord  plug  is  not  connected 

properly  and  electric  power  is  off. b. 

MIST switch is off. 

a.  Ensure  that  the  power  cord  plug  is 

fully  inserted  into  the  electrical  outlet 

and  turn  on  the  electric  power. b.  Turn 

on the MIST switch. 

2.  The  ultrasonic  transducer  is  working 

properly but how come there is no mist 

spray? 

a. Water tank is broken or with crack, so 

flume  is  full  of  water. b.  Fan  is  not 

working. 

a.  Pour  out  the  water  from  flume, 

change a new water tank. b. Change a 

new fan motor. 

3. Why is there no mist even though fan 

is working? 

a.  No  water  or  water  level  is  not 

enough. b.  Bobber  doesn’t  float  in  the 

water. c.  Ultrasonic  transducer  surface 

was  filled  up. d.  Clamp  plate  of  water 

level  switch  is  not  firmly  positioned  in 

place. e.  Ultrasonic  transducer  is 

damaged. 

a.  Add  water.   b.  Pull  out  the  bobber 

and  let  it  float  out. c.  Clean  ultrasonic 

transducer  with  detergent  supplied 

together with product. d. Reinstall clamp 

plate  of  water  level  switch. e.  Change 

the ultrasonic transducer.  

4. Why is there a peculiar smell of mist? a.  Peculiar  smell  of  new  product will 

disappear  after  a  period  of  using. b. 

Dirty water or water storage time is too 

long. 

a.  Take  out  the  tank  and  open  tank 

cover, and put it to a ventilated and dry 

place. b.  Clean  water  tank  and  flume 

and change the clean water. 

5. Why is the fan not operating? 

a.  The  plug  inserted  may  be  lacking 

electricity or fuses may have gone off. 

a. Make sure the plug works and check 

your fuses. 

6.Heavy unit vibration. 

a.  The  rear  guard  is  not  installed 

tightly. b. The blade cap is loosened. c. 

The  blade  is  damaged. d.  The  blade  is 

not aligned 

a.  Install  the  rear  guard  tightly. b. 

Tighten the blade cap. c. Change a new 

fan  blade. d.  Turn  the  fan  blade  180° 

and then reinstall blade. 

7. Other unusual problem. 

a. Motor appeared smoke or a smell of 

burnt. b.  Exposed  metal  parts  with 

electric  or  the  fan  insulation  is 

damaged. c. The rear cover of motor is 

damaged. 

a.b.c.  Stop  using  and  send  to  service 

agent for repair. 

 

 

 

 

 

LAVA AIRE 

I T A L I A

Manufactured for: www.LavaHeat.com

JR ZIONI DESIGNER

Summary of Contents for Fantom

Page 1: ...nt Working Principle The Ultrasonic mist fan uses supersonic concussive elements that atomize water down to 1 5 micron ultra particles and through the industrial fan it spreads the ultrasonic mist into the air and thus cooling down the room temperature 1 Front grille guard ornament 2 Front guard 3 Blade cap 4 Blade 5 Guard mounting nut 6 Rear guard 7 Motor 8 Iron tube upper 9 Iron tube connector 1...

Page 2: ...ar guard tightly by turning the guard mounting nut clockwise Assembly of fan blade 1 Insert the blade to the motor shaft and ensure the pin enters the blade slot 2 Tighten the blade using the blade cap turning it counter clockwise in the direction with a TIGHT arrow indicated on it Note Proper assembly of the blade is of great importance Otherwise the blade spins out of direction and can cause dam...

Page 3: ...he tank if the unit is turned on 4 Do not insert any object into guard and mist spray hole to avoid destroying the unit 5 Unplug the unit from the electrical outlet when not operating and before moving installing uninstalling and cleaning the unit 6 Do not pull the plug while the power is on Always ensure that the plug is fully inserted into the electrical outlet before operating 7 Do not add any ...

Page 4: ...e a new water tank b Change a new fan motor 3 Why is there no mist even though fan is working a No water or water level is not enough b Bobber doesn t float in the water c Ultrasonic transducer surface was filled up d Clamp plate of water level switch is not firmly positioned in place e Ultrasonic transducer is damaged a Add water b Pull out the bobber and let it float out c Clean ultrasonic trans...