LAUNCH X-712 Wheel Aligner Operation Instructions
4-13
view for the standard data of the vehicle model.
Frequent Model
In order to speed up the information search, the system
provides the commonly used data management function
which can individually add the vehicle information in the
standard data into the commonly used data. The
interface is as shown in Fig.4.43.
Fig.4.43
[Added from the standard data]: Click this button, the
standard data window will be activated. Select the
required vehicle model from the standard data list. After
confirming, the information can be added from the
standard data to the commonly used data list.
[Delete]: Delete the items selected from the commonly
used data.
System Setting
System setting function is used to adjust the function
and display effect of software system. The interface is as
shown in Fig.4.44.
Fig.4.44
[Basic setting]: With this function the system can be
switched between Normal Version and Demo Version,
and between Expert and New Learner. [Normal version]:
is the version directly applied in actual testing operation;
[Demo version]: this version can, in stand-alone status,
simulate the testing process without external hardware
equipments, it hasn't testing ability, only used to
demonstrate the testing process; [New learner]: this
version provides all-around HELP information and
operating demo animation to fully help the testing
personnel who contacts this system for the first time;
[Expert]: for experienced operator, too much HELP
information will, on the contrary, become
encumbrance, so this version provides the necessary
HELP information only to make the operator be working
with more high efficiency. Also the system provides the
options of directly turning off PC or quitting to
WINDOWS when quitting the system.
[Database setting] the system provides two types of
Database setting: 1) Oftendata; 2) Normaldata.
[Kingpin turning operation]: the system provides two
types of kingpin measurement: 1) 20 degrees; 2) 10
degrees.
[Unit setting]: Used to set the displayed unit system of
system data, two types of unit systems can be selected:
percentage degree system and degree/minute system.
[Unit setting for toe-in]: Aiming to the particularity of the
unit for toe-in, the system adds the units of mm and
inch.
Note:
If you want to use long measure as the unit of toe-in,
during performing standard measurement, the
system will require the operator to enter the
diameter of the tires when entering the operating
interface of Select Vehicle Model.
Report setting
Report setting can set the format type of the report form.
The interface is as shown in Fig.4.45.
Fig.4.45
[Report form 1]: Format 1 is for detailed report form,
which includes the items of Before Adjustment, After
Adjustment, Standard maximum and minimum values.
[Report form 2]: Format 2 is for concise report form,
which lists the data information before and after
adjustment only.
Delete
Added from the
standard data
Summary of Contents for X-712
Page 1: ...V2 01 000 2012 09 10 For X 712 X 712 Short Column X 712 Wall mounted X 712HD...
Page 13: ...LAUNCH X 712 Wheel Aligner Structures 2 2 Fig 2 1 b X 712 Short Column Wheel Aligner...
Page 14: ...LAUNCH X 712 Wheel Aligner Structures 2 3 Fig 2 1 c X 712 Wall mounted Wheel Aligner...
Page 15: ...LAUNCH X 712 Wheel Aligner Structures 2 4 Fig 2 1 d X 712HD Wheel Aligner...