X-431 ADAS PRO Calibration Tool User Manual
46
Proceed as follows to place the ADAS calibration panel in parallel with the vehicle:
1. Switch on the laser beam of the laser module with the switch.
2. Align the laser beam of the laser module on the cross member with the scale of the
wheel clamp. The laser beam will be projected onto the scale of the wheel clamp.
3. Perform step 1-2 with the second laser beam.
4.
By axially turning the calibration frame, place the frame in a way that the left
and right scale of the wheel clamp reflected from the laser modules on the
cross member show the same values.
Fig. 5-8
Now the calibration panel is placed in parallel with the vehicle.
5.2.1.4 Set up the height of the calibration frame
Place the laser distance meter (In ON state) in position and keep the screen facing
down. Use the Rocker switch on the beam lifter to move the calibration panel up to the
height indicated in the diagnostic tool (Fig. 5-3). Alternatively, user also can refer to the
back label (The greater value displayed on the scale indicates the actual height)
located on the back of the beam lifter.
Fig. 5-9