Launch TLT235
、
TLT240 Economical Two-post User’s Manual
11
4.2 Electrical System of the Lift
Diagram of electrical system for single phase motor
M1-Motor KM-Contactor SB –Button SQ- Limit switch
Fig. 5a
Diagram of electrical system for three phase motor
M1-Motor KM-Contactor SB –Button SQ- Limit switch
Fig. 5b
The electrical working principle is as follows:
Press the start button (SB), and the contactor (KM) will be
powered; motor (M) is energized to drive the gear pump
supplying oil to push the carriage upward; release the start
button, and the contactor (KM) is open, then the motor (M)
will lose the power, so the carriage will stop rising. As for
the clear-floor lift, if the vehicle is lifted up to the top and
contacts the limit switch on the top beam, the contactor
(KM)) will open, then the motor (M) will lose the power, so
that the carriage stops lifting. Emergency stop button to
emergency power-off function.
Summary of Contents for TLT235
Page 11: ...Launch TLT235 TLT240 Economical Two post User s Manual 4 Fig 1b Fig 1c...
Page 12: ...Launch TLT235 TLT240 Economical Two post User s Manual 5 Fig 2a Fig 2b...
Page 30: ...Launch TLT235 TLT240 Economical Two post User s Manual 23 Fig 14a...
Page 36: ...Launch TLT235 TLT240 Economical Two post User s Manual 29 Applicable to TLT235SB TLT240SB...
Page 37: ...Launch TLT235 TLT240 Economical Two post User s Manual 30 Applicable to TLT235SB TLT240SB...
Page 38: ...Launch TLT235 TLT240 Economical Two post User s Manual 31 Applicable to TLT235SC TLT240SC...
Page 46: ...Launch TLT235 TLT240 Economical Two post User s Manual 39 1 packing 1 packing Domestic...