background image

LAUNCH                                                          KWB-421 Wheel Balancer User’s Manual 

2.2 Recommendations 

 

Voltage stabilizing power is recommended to use in the area where have not a stable power supply. 

 

Before starting to use the balancing machine, carefully read the operating instruction manual. Keep the 

manual in a safe place for future reference. Consult the technical person for any misunderstanding.   

 

Do  not  uninstall  or  replace  the  parts  without  the  instruction  of  the  technical  person,  otherwise  the 

regular operation of the machine could be affected. 

 

Do not clean the machine by compressed air with exceeded pressure. 

 

Use detergent to clean plastic panels and shelves termly. 

 

The machine operator should not wear necktie, long hair or loose cloth. She or he should stand at the 

side face of the machine and make sure that unauthorized personnel do not approach the machine 

during the work cycle. 

 

The balancing machine should not be used for purposes other-than those described in the instruction 

manual. 

 

All the electrical installation should be operated by professional electrician . 

 

Make  sure  that  the  ground  wire  has  a  reliable  ground  connection,  and  cut  off  the  power  when  the 

maintenance and repair operation is on. 

 

Circumstance requirement: Temperature: 0

℃-

50

℃,

dry and drafty.   

3. Cotrol Panel 

 

 

I. Digital display, AMOUNT OF UNBALANCE, inside 

II. Digital display, AMOUNT OF UNBALANCE, outside 

III. Indicator, POSITION OF UNBALANCE, inside 

. Indicator, POSITION OF UNBALANCE, outside 

. Indicators, correction mode selected 

Summary of Contents for KWB-421

Page 1: ...V1 00 000 2018 08 18...

Page 2: ...purposes only and the registered trademark ownership belongs to original companies This equipment is intended for use by technical professionals or maintenance personnel Trademark Information is a reg...

Page 3: ...d Installation 3 2 1 Haulage and installation of the machine 3 2 2 Recommendations 4 3 Cotrol Panel 4 4 Operation 5 4 1 Wheel Mounting 5 4 2 Input the Wheel Data 6 4 3 Balance Mode Selection 7 4 4 Whe...

Page 4: ...lf calibration and full automatic failure diagnosis function 1 3 Technical Data Max wheel weight 65kg Max tire diameter 650mm Power supply 220V Noise 70dB Balancing accuracy 1g Rim width 1 5 18 Rim di...

Page 5: ...s termly The machine operator should not wear necktie long hair or loose cloth She or he should stand at the side face of the machine and make sure that unauthorized personnel do not approach the mach...

Page 6: ...ers for weight fixing removing or any other pointed objects 4 Operation Turn on the main power the balancer begins the interior self diagnostic program If A 8 0 is displayed on the display window the...

Page 7: ...attention to the direction else measurement error could be possible 4 2 Input the Wheel Data I Input the measurement data A II Input measurement data L On the measure statue pull out the slide ruler...

Page 8: ...r key to plus or minus a defined value to change the displayed figure till equal to the d figure Dynamic balance This is used in testing dynamic imbalance when the wheel running and to eliminate the i...

Page 9: ...For example outside screen displays 10g inside screen displays 40g outer imbalance value inner imbalance value Turn the wheel slowly by hand to locate the balanced point make sure that all the balanc...

Page 10: ...s plant This operation could be re do if the machine services too many years or the spares are charged or there is a big imbalance value Install a middle scale wheel which has a rim diameter 13 or 14...

Page 11: ...lue 1 The wheel has a big error value 1 Use a balanced wheel When the self calibration ends there is too big imbalance value for the 100g lead block or the position is not on the positive down or too...

Page 12: ...ed forward the sensor is wrong 1 Adjust the phase 2 Readjust the position or change another one Err5 displayed The wheel shield is not put down Put down the shield Err7 displayed EMS memory data lose...

Page 13: ...a sensor 2 Re do self calibration The balancer can not brake when the value displayed 1 The brake system is damaged 2 There is a disturb 1 Change a power board 2 Reset the machine There is a differenc...

Page 14: ...LAUNCH KWB 421 Wheel Balancer User s Manual 13 6 The Wiring Diagram of the Power Board Connected to transformer...

Page 15: ...ative of LAUNCH has any authority to bind LAUNCH to any affirmation representation or warranty concerning LAUNCH products Declaration The above warranty is able to replace any warranty in other forms...

Reviews: