background image

LAUNCH                                                          KWB-421 Wheel Balancer User’s Manual 

11 

5.2 Wheel Balancer Troubleshooting 

 

Error Descriptions 

Reasons 

Solutions 

Screen no display during 
start 

1.The switch is wrong 
2. External circuit is wrong 

1.Change another one 
2. Check the electric power circuit 
with multi-meter. 

Display normal, but 

the machine can not 
start and with some 
noise , Err1 displayed 

1.The capacitor of the electric machine 

is disabled 
2.380V power with no enough phase 

1.Change capacitor 20UF/400V 
2.Check the power 

Err2 displayed 

1.The wheel is not installed 

2. Install the rim but with no tyre. 
3. The adaptor is not tightened. 
4. The wheel is not installed correctly or 

it is not tightened. 
5. The belt is over loose or tight. 

1.Install the wheel 
2.Install the tyre 
3.Tighten the anchor screw 

4.Install a suitable adaptor 
5.Readjust the belt 

Err3 displayed 

The wheel has a too big imbalance 

value 

Change another wheel or do the 

self-calibration again.   

Err4 displayed 

1. If the wheel turned reversely, the 

phase wire is wrong connected. 
2. If the wheel turned forward, the 
sensor is wrong.     

1.Adjust the phase 

2.Readjust the position or change 
another one 

Err5 displayed 

The wheel shield is not put down 

Put down the shield 

Err7 displayed 

EMS memory data lose 

Do the self-calibration again 

Only display “00-00”,no 
values displayed 

1.The wire of the sensor is cut off or it 
is not well connected 
2.EMS memory data lose 

1.Connect the wire 
2.Refer to the manual, correct the 
EMS memory value 

The value of variable 
range exceeds 5 grams 

when the wheel turns. 

1.The wheel is not clean or the fitting 
surface of the rim center hole is 

distorted 
2.The sensor is wet or the lock nut is 
loose   

3. The voltage is lower or the air 
pressure of the tyre is low or the 
adaptor is not tightened or the cabinet 

is not fixed on the ground.   

1.Change a wheel 

2.Drying it or readjust the sensor 
3. Install voltage stabilizer; charge the 
tyre; tighten the flange or the adaptor 

by a lock nut; fix the cabinet on the 
ground. 

The value of variable 
range reaches tens of 
grams when the wheel 

turns. 

1.The wheel is not clean or the 
imbalance value is too big. 
2.The sensor is out of action 

3.The voltage is lower 

1.Change a wheel 
2.Check the sensor and the 
connection 

Check the power or install a voltage 
regulator 

Summary of Contents for KWB-421

Page 1: ...V1 00 000 2018 08 18...

Page 2: ...purposes only and the registered trademark ownership belongs to original companies This equipment is intended for use by technical professionals or maintenance personnel Trademark Information is a reg...

Page 3: ...d Installation 3 2 1 Haulage and installation of the machine 3 2 2 Recommendations 4 3 Cotrol Panel 4 4 Operation 5 4 1 Wheel Mounting 5 4 2 Input the Wheel Data 6 4 3 Balance Mode Selection 7 4 4 Whe...

Page 4: ...lf calibration and full automatic failure diagnosis function 1 3 Technical Data Max wheel weight 65kg Max tire diameter 650mm Power supply 220V Noise 70dB Balancing accuracy 1g Rim width 1 5 18 Rim di...

Page 5: ...s termly The machine operator should not wear necktie long hair or loose cloth She or he should stand at the side face of the machine and make sure that unauthorized personnel do not approach the mach...

Page 6: ...ers for weight fixing removing or any other pointed objects 4 Operation Turn on the main power the balancer begins the interior self diagnostic program If A 8 0 is displayed on the display window the...

Page 7: ...attention to the direction else measurement error could be possible 4 2 Input the Wheel Data I Input the measurement data A II Input measurement data L On the measure statue pull out the slide ruler...

Page 8: ...r key to plus or minus a defined value to change the displayed figure till equal to the d figure Dynamic balance This is used in testing dynamic imbalance when the wheel running and to eliminate the i...

Page 9: ...For example outside screen displays 10g inside screen displays 40g outer imbalance value inner imbalance value Turn the wheel slowly by hand to locate the balanced point make sure that all the balanc...

Page 10: ...s plant This operation could be re do if the machine services too many years or the spares are charged or there is a big imbalance value Install a middle scale wheel which has a rim diameter 13 or 14...

Page 11: ...lue 1 The wheel has a big error value 1 Use a balanced wheel When the self calibration ends there is too big imbalance value for the 100g lead block or the position is not on the positive down or too...

Page 12: ...ed forward the sensor is wrong 1 Adjust the phase 2 Readjust the position or change another one Err5 displayed The wheel shield is not put down Put down the shield Err7 displayed EMS memory data lose...

Page 13: ...a sensor 2 Re do self calibration The balancer can not brake when the value displayed 1 The brake system is damaged 2 There is a disturb 1 Change a power board 2 Reset the machine There is a differenc...

Page 14: ...LAUNCH KWB 421 Wheel Balancer User s Manual 13 6 The Wiring Diagram of the Power Board Connected to transformer...

Page 15: ...ative of LAUNCH has any authority to bind LAUNCH to any affirmation representation or warranty concerning LAUNCH products Declaration The above warranty is able to replace any warranty in other forms...

Reviews: