Lauda WK 500 Operating Instructions Manual Download Page 15

LAUDA Water Circulation coolers
WK, WKL

YAWE0019/18.12.01

- 14 -

Refrigeration and tempering circuit diagram

* außer / except / sauf  WK 500, WK 502, WKL 600, WKL 603, WKL 700, WKL 703

Kältekreislauf (

 Anhang)

Schema cooling circuit (

Annex)

Schéma de réfroidissement (

Annexion)

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for WK 500

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...e Internet http www lauda de Operating instructions LAUDA Water Circulation coolers WK 500 WK 502 WK 1200 WK 1400 WK 2200 WK 2400 WK 3200 WK 4600 WK 7000 W WK 10000 W WKL 230 WKL 600 WKL 603 WKL 700 W...

Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 4: ...SE CONNECTIONS 16 5 1 Bath liquids 16 5 2 Hose connections by the metre 17 6 UNPACKING ASSEMBLY AND SETTING UP 18 7 FILLING AND CONNECTION OF EXTERNAL CONSUMING DEVICES 19 8 STARTING UP 20 9 MAINTENAN...

Page 5: ...bes with hose clips against slipping off Use only tubes suitable for the liquid used and for the maximum operating pressure Check the supply voltage against the details on the label Insert the mains p...

Page 6: ...2A Pump output max 30 33 40 30 40 30 Discharge pressure max bar 1 2 2 3 2 1 3 2 1 Pump connections for tubing i d M 16x1 10 M 16x1 10 G 15 G 15 G 15 G 15 Supply pressure Indication Range Adjustment b...

Page 7: ...2 3 2 3 2 3 2 Pump connections for tubing i d G 15 G 15 G 15 G 15 G 15 G 15 Supply pressure Indication Range Adjustment bar analogue 0 6 adjustable bypass for pressure limitation Filling capacity max...

Page 8: ...contact max 30 V 2A Pump output max 8 30 33 30 33 40 40 Discharge pressure max bar 0 15 1 3 2 1 3 2 3 2 3 2 Pump connections for tubing i d 10 8 M 16x1 10 M 16x1 10 M 16x1 10 M 16x1 10 G 15 G 15 Supp...

Page 9: ...40 40 60 60 60 60 Discharge pressure max bar 3 2 3 2 6 0 6 0 6 0 6 0 Pump connections for tubing l W G 15 G 15 G 1 20 1 G 1 20 1 G 1 20 1 G 1 20 1 Supply pressure Indication Range Adjustment bar anal...

Page 10: ...Regler Temperature indication and controller Affichage de temp rature et r gulateur Netzschalter Mains swich Interrupteur g n ral Bypass Ventil Bypass valve Venne bypass Pumpenstutzen Pump nozzles Tu...

Page 11: ...e indication and controller Affichage de temp rature et r gulateur Netzschalter Mains swich Interrupteur g n ral Alarmkontaktausgang Alarm contact ouput Contact alarme Bypass Ventil Bypass valve Vanne...

Page 12: ...nt of the discharge flow through the external circuit A temperature probe inside the bath measures the temperature which is indicated digitally The temperature setpoint is selected digitally The contr...

Page 13: ...7000 W WK 10000 W Very powerful devices with water cooled condenser All WKL models have a working temperature range expanded under 0 C and are with temperatures around 0 C more efficient than comparab...

Page 14: ...ics WKL 230 WKL 603 WKL 703 WK 502 WK 500 WKL 600 WKL 700 WK 1400 WK 2400 WK 1200 WK 2200 WK 3200 WK 4600 WK 7000 W WK 10000 W WKL 1200 WKL 2200 WKL 3200 WKL 4600 WKL 7000 W WKL 10000 W Artisan Techno...

Page 15: ...and tempering circuit diagram au er except sauf WK 500 WK 502 WKL 600 WKL 603 WKL 700 WKL 703 K ltekreislauf Anhang Schema cooling circuit Annex Sch ma de r froidissement Annexion Artisan Technology...

Page 16: ...1 Operation only at industrial areas Class B according to EMC standard EN 61326 1 Operation suitable for domestic areas Class B according to EMC standard EN 61326 1 Thermostat fulfills class B when a...

Page 17: ...at higher temperatures the proportion of water decreases The mixture approaches the properties of pure glycol and becomes flammable flashpoint 128 C The mixture ratio should therefore be checked from...

Page 18: ...40 80 all bath liquids all units with M16x1 and 13 mm connector RKJ 031 Rubber tubing fibre strengthened 40 80 all bath liquids all units with connector RKJ 032 Rubber tubing fibre strengthened 1 40...

Page 19: ...quick release coupling at WK L 7000 W an at WK L 10000 W only in case of water cooled devices Operating Instructions The unit should be set up with the operating panel at the front the ventilation gri...

Page 20: ...the back of the unit to the external circuit Only pressure tight circuits can be connected to the chiller Switch off the unit before loosening the hose connections The hose couplings do not close aut...

Page 21: ...is always closed as the maximum pressure is 1 0 bar The following method may be used to prevent a certain pressure being exceeded even if the external circuit gets blocked Close off the outflow make a...

Page 22: ...r start of the compressor Put the outlet tubing maximally low so that the device is completely emptied Switch off the device immediately again 9 2 Trouble shooting and safety notes For all other maint...

Page 23: ...carrying out an appropriate detoxification of any dangerous material which has been spilled on or in the unit This applies in particular when the unit is passed on to someone else for operation repair...

Page 24: ...No LWZ 010 For units with connections G tubing VT 3 Ref No LWZ 022 For units with connections G1 1 4 tubing VT 4 Ref No LWZ 024 Nipple for pump connections 11 for tubing 8 10mm for WK 500 WK 502 WKL...

Page 25: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 26: ...e Serien Nr Serial no No de s rie mit folgendem Medium betrieben wurde was used with the below mentioned media a t utilis avec le liquide suivant Dar ber hinaus best tigen wir da das oben aufgef hrte...

Page 27: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: