Lauda LRZ 918 Operation Manual Download Page 23

12 

Accessories

The following LAUDA accessories are available for Pt100/LiBus modules:

Article

Catalog number

LiBus module box; Extension of constant temperature equipment by up to two interface

modules with large cover

LCZ 9727

Pt100
LEMO connecting plug, 4-pin (NAMUR standard)

EQS 022

Connecting cable with 2 LEMO connecting plugs, 2.5 m

UK 246

Platinum resistance thermometer with LEMO socket,
Stainless steel version according to DIN EN 60751, accuracy class A:
Pt100-70, length 250 mm, diameter 4 mm,
Temperature range -200...300 °C, half-life 1/s

ETP 009

Pt100-80, length 150 mm, diameter 1.9 mm,
Temperature range -200...300 °C, half-life 1/s

ETP 012

Pt100-90, length 80 mm, diameter 4 mm,
Temperature range -100...300 °C, half-life 1.5/s

ETP 050

Pt100-94, length 250 mm, diameter 4 mm,
Temperature range -100...300 °C, half-life 1.5/s
(with permanently attached silicone line, length 2 m)

ETP 059

LiBus
LiBus T-extender with 2 LiBus sockets

EKS 073

LiBus extension cord, 5 m

EKS 068

LiBus extension cord, 25 m

EKS 069

V1

Interface module LRZ 918 / 925

23 / 25

Summary of Contents for LRZ 918

Page 1: ...Interface module LRZ 918 925 LRZ 918 Pt100 LiBus module small cover Operation manual LRZ 925 Pt100 LiBus module large cover V1R47 Read this manual prior to performing any task ...

Page 2: ...rer LAUDA DR R WOBSER GMBH CO KG Laudaplatz 1 97922 Lauda Königshofen Germany Telephone 49 0 9343 503 0 Fax 49 0 9343 503 222 E mail info lauda de Internet https www lauda de Q4DA E_13 015 1 en_US 10 19 2021 LAUDA 2021 V1 Interface module LRZ 918 925 2 25 ...

Page 3: ...Unpacking 9 4 Device description 10 4 1 Purpose 10 4 2 Structure 10 4 3 Coding switch 11 5 Before starting up 12 5 1 Installing the interface module 12 5 2 Using the module box 14 6 Commissioning 15 6 1 Contact assignment 15 6 2 Software update 16 7 Operation 17 7 1 Pt100 interface 17 7 2 LiBus interface 17 8 Maintenance 18 9 Faults 19 9 1 Error 19 9 2 Warning 20 10 Decommissioning 21 11 Disposal ...

Page 4: ...UDA constant temperature equipment It may only be installed in con stant temperature equipment that supports the interface provided Refer to the chapter Compatibility in this operating manual for a list of compatible product lines Operation of the interface module is also permitted in combination with the LiBus module box LAUDA catalog no LCZ 9727 This operating manual also contains a description ...

Page 5: ...ight This operating manual was written in German checked and approved If the content of other language editions deviates from the German edition the information in the German edition shall take precedence If you notice any discrepancies in the content please contact LAUDA Service see Ä Chapter 1 6 Contact LAUDA on page 6 Company and product names mentioned in the operating manual are usually regis...

Page 6: ...oting Technical questions Ordering accessories and spare parts Please contact our sales department for questions relating to your specific application Contact information LAUDA Service Phone 49 0 9343 503 350 Fax 49 0 9343 503 283 Email service lauda de V1 Interface module LRZ 918 925 6 25 ...

Page 7: ...ty instructions in this operating manual must be observed without fail There are also certain requirements for personnel see Ä Chapter 2 3 Personnel qualification on page 8 Warning signs Type of danger Warning danger zone Signal word Meaning DANGER This combination of symbol and signal word indicates an imminently dangerous situation that will result in death or serious injury if it is not avoided...

Page 8: ... screen on the cables and connec tors complies with EMC regulations LAUDA recommends using pre assembled cables Always lay cables correctly so that they do not pose a tripping hazard Secure the laid cables and make sure that they cannot be damaged during operation Check the condition of the cables and interfaces prior to each opera tion Immediately clean any soiled parts in particular unused inter...

Page 9: ...ng installation sequence 1 Remove the interface module from its packaging 2 If you want to store the interface module at the installation location use the outer packaging This packaging is protected against static charging 3 After installing the equipment dispose of the packaging materials in line with environmental regulations see Ä Packaging on page 22 If you discover any damage on the interface...

Page 10: ...n LiBus stands for LAUDA internal BUS and refers to the CAN based fieldbus system used in LAUDA equip ment 4 2 Structure 1 LiBus socket 4 pin 2 Cover with holes for fastening screws 3 Pt100 socket LEMO 1S series 4 pin Refer to Ä Pt100 interface on page 15 and Ä LiBus interface on page 16 for more information on contact assignment Fig 1 Pt100 LiBus module LRZ 918 Fig 2 Pt100 LiBus module LRZ 925 V1...

Page 11: ... Pt100 interface is assigned the name External Pt100 2 Positions 2 9 Currently without any function Only change the setting if you want to use this Pt100 LiBus module to operate a second external temperature probe on the constant temperature equipment Check the coding switch setting before installing the Pt100 LiBus module in constant temperature equipment Setting the address of the second Pt100 i...

Page 12: ...es to all LAUDA constant temperature equipment the example diagrams here show the installation of an analog module in constant temperature equip ment from the Variocool product line Please note that an interface module with a small cover can only be installed in a low module slot The fitted cover must cover the opening on the module slot completely You will require two M3 x 10 screws and a suitabl...

Page 13: ...ke sure that the lug on the plug is aligned with the recess in the socket The interface module is correctly connected to the constant tem perature equipment 6 Slide the LiBus ribbon cable and the interface module into the module slot 7 Secure the cover to the casing using two M3 x 10 screws The new interface on the constant temperature equipment is ready for operation Fig 5 Detaching the LiBus rib...

Page 14: ...y 3 Check which interfaces are already present on the constant tem perature equipment and module box Observe the information on interface module compatibility Only install an interface module with the same type of inter face if operation with several of these interfaces is permitted 4 Install the required interface module in the module box Please read the information on installing the module box i...

Page 15: ...example use double or reinforced insulation according to DIN EN 60730 1 or DIN 60950 1 Refer to Ä Chapter 12 Accessories on page 23 for accessory information on assembling connection cables The Pt100 interface is designed as a 4 pin circular connector with screw plug LEMO Table 1 Contact assignment of Pt100 interface Contact Function 1 I current path 2 U voltage path 3 U voltage path 4 I current p...

Page 16: ...ate Older software installed on constant temperature equipment may have to be updated for the new interface to work 1 Switch on the constant temperature equipment after installing the new interface 2 Check whether a software warning appears on the display Warning SW too old Please contact LAUDA Service see Ä Chapter 1 6 Contact LAUDA on page 6 No software warning Operate the constant temperature e...

Page 17: ...ontrol the temperature control process via the external Pt100 temperature probe Offset source Control is based on the measured value provided by the Pt100 temperature probe However the control set point is generated by adding the Pt100 measured value to a specified offset value Follow the instructions for configuring external control variables in the operating manual accompanying the constant temp...

Page 18: ...ng any cleaning work Water and other fluids should not be allowed to enter the device NOTICE Repairs performed by unauthorized persons Material damage Only specialized personnel are permitted to carry out repairs 1 Use a damp cloth or brush to remove any dust and dirt deposits 2 When using compressed air Always set a low working pressure to prevent mechanical damage to the connections If you have ...

Page 19: ...tment 1705 2005 Clock frequency incorrect 1706 2006 Distribution voltage too low 1707 2007 Distribution voltage too low 1708 2008 Backup memory faulty 1710 2010 2 point calibration Upper lower point mixed up 1711 2011 2 point calibration Difference between upper lower measuring point too small 1712 2012 2 point calibration Difference between upper lower correction point too small 1713 2013 2 point...

Page 20: ...e faulty replace the temperature probe 1707 2007 Implausible parameter detected 1708 2008 Bus system faulty 1709 2009 Unknown module detected 1710 1732 2010 2032 Software of component outdated Contact the LAUDA department Error prefix 17 applies for interface Pt100 error prefix 20 for Pt100 2 see Ä Chapter 4 3 Coding switch on page 11 V1 Interface module LRZ 918 925 20 25 ...

Page 21: ...ace module on page 12 Proceed in reverse order to remove 2 Always attach the LiBus connecting cable to the inside of the module slot cover 3 Fit the cover to the vacant module slot to protect the constant temperature equipment against the ingress of dirt 4 Protect the interface module against static charging before placing it in storage The storage location must meet the ambient conditions specifi...

Page 22: ...4 62 EC packaging and packaging waste if disposing of the product in a member state of the EU The device must be properly decommissioned and disposed of at the end of its life cycle 1 Dispose of the device in accordance with the applicable disposal guidelines in your region 2 Comply with Directive 2012 19 EU WEEE Waste of Electrical and Electronic Equipment if disposing of the product takes place ...

Page 23: ...rsion according to DIN EN 60751 accuracy class A Pt100 70 length 250 mm diameter 4 mm Temperature range 200 300 C half life 1 s ETP 009 Pt100 80 length 150 mm diameter 1 9 mm Temperature range 200 300 C half life 1 s ETP 012 Pt100 90 length 80 mm diameter 4 mm Temperature range 100 300 C half life 1 5 s ETP 050 Pt100 94 length 250 mm diameter 4 mm Temperature range 100 300 C half life 1 5 s with p...

Page 24: ...mm 56 x 20 x 80 56 x 40 x 80 Weight kg 0 1 Operating voltage V DC 24 Maximum current consumption A 0 1 LiBus socket Version 4 pin Pt100 socket Version LEMO 1S series 4 pin Ambient conditions Air humidity Maximum relative air humidity 80 at 31 C and up to 40 C 50 with linear decrease Ambient temperature range C 5 40 Temperature range for storage C 5 50 V1 Interface module LRZ 918 925 24 25 ...

Page 25: ...nterface Connection 16 Operation 17 M Module box 14 Module slot 12 P Personnel qualification overview 8 Pt100 interface Contact assignment 15 Error 19 Operation 17 Warning 20 Pt100 LiBus module Accessories 23 Coding switch 11 Compatibility 4 Purpose 10 Structure 10 S Safety information General 7 Interface module 8 Service 6 Software update 16 T Technical changes 5 U Update 16 W Warning 20 Warranty...

Page 26: ...Manufacturer LAUDA DR R WOBSER GMBH CO KG Laudaplatz 1 97922 Lauda Königshofen Telephone 49 0 9343 503 0 Fax 49 0 9343 503 222 E mail info lauda de Internet https www lauda de ...