background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for Ecoline Series

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...Phone 49 0 9343 503 0 Fax 49 0 9343 503 222 e mail info lauda de Internet http www lauda de Operating Instructions Ecoline Immersion thermostats E 100 Bath Circulation thermostats E 106 T E 112 T E 11...

Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 4: ...e equipment if it is damaged or leaking the supply cable is damaged Switch off the equipment and pull out the mains plug for servicing or repair the supply cable is damaged Drain the bath before movin...

Page 5: ...oling the thermostats 13 6 STARTING UP 14 6 1 Connection to the supply 14 6 2 Switching on 14 6 3 Setpoint selection 15 6 4 Menu functions 16 6 4 1 Pump output 16 6 4 2 User calibration 17 6 5 Warning...

Page 6: ...ntenance and repair 24 8 3 Ordering spares 25 9 TECHNICAL DATA TO DIN 58966 26 10 ACCESSORIES 29 11 CIRCUIT DIAGRAM 31 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www art...

Page 7: ...ecommendation is not followed accurately or is disregarded Note Here special attention is drawn to some aspect May include reference to danger Reference Refers to other information in different Sectio...

Page 8: ...nit with corresponding liquid Section 5 3 The units are designed for operation with non flammable and flammable liquids to EN 61010 2 010 Take care of the level of the bath liquid Section 5 2 3 Connec...

Page 9: ...for bath circulation Jet nozzle Heater Heating LED green Supply ON Menu functions Mains switch Setting of overtemperature switch off point Pump connections inlet Pump connections outflow Cooling coil...

Page 10: ...By turning the setting knob it is possible to choose between both outlets or to divide the flows The pump chamber of immersion thermostats is rotatable in a restricted way to reach an optimal circula...

Page 11: ...es are stored in the memory on supply failure or when the mains switch is set to OFF The tubular heater is controlled from a modified PID controller through a triac circuit specially designed to be un...

Page 12: ...o be moved upwards approx 15 mm Adjust the pump chamber Move the fixation of the temperature probe downwards again see ill on the left For all LAUDA baths plastic and deep drawn baths please fix the a...

Page 13: ...er Section 5 4 The immersion thermostats have to be fixed carefully at the bath for they must not fall into the bath In that case don t touch the bath liquid Pull out mains plug immediately a Bath Cir...

Page 14: ...the return 5 2 Filling and emptying Filling Fill baths up to a maximum level of 20 mm below the bath bridge Optimum operation at 20 40 mm below the bath bridge Operation is possible down to 60 mm bel...

Page 15: ...liquids to EN 61010 2 010 Flammable liquids can be operated up to no more than 25 C below the firepoint Section 5 3 Observe the appropriate regulation when disposing used thermostating liquid When con...

Page 16: ...bath covers Section 10 Accessories Distilled water or fully deionised water must only be used with the addition of 0 1g sodium carbonate Na2CO3 l water otherwise danger of corrosion Water content fal...

Page 17: ...or all bath liquids LZS 008 Silicone tubing uninsulated 11 30 to 100 water water glycol mixture RKJ 059 Silicone tubing insulated 11 ext dia 35mm approx 60 to 100 water water glycol mixture LZS 007 Vi...

Page 18: ...in accordance to the thermostating task Section 5 1 Position maximum flow in the external circuit the setting knob is turned anticlockwise Position flow passes through pump outflow and outlet for bat...

Page 19: ...cross section in the external circuit When the external consumer is placed at a higher level than the thermostat the pump is stopped and air penetrates into the thermostating circuit the external liqu...

Page 20: ...cooling coil as standard Cooling possibilities down to 20 C Mains water keep the water consumption as low as possible down to 20 C flow through cooler DLK 10 DLK 25 depending on bath size and tempera...

Page 21: ...e ambient temperature Switch on at the mains switch The green LED for Supply ON lights up 0 25s A tone sounds for approx 0 25 s The unit self test starts up All display segments and symbols light up f...

Page 22: ...etpoint using the keys Speeding the setting process by a continuous pressing the keys or b pressing one key holding it down and shortly pressing the other key Briefly releasing 1 s the key s and again...

Page 23: ...utput Display shows P and actual pump output step Press the key display flashes approx 4 s or During this time start to set the required step with the keys 0 pump stopped heating off 1 low pump output...

Page 24: ...lts after 2 min EEE changing with 1006 or 16 The factory calibration will be lost through overwriting please work carefully and 1x Directly from level 0 actual value display press key combination on t...

Page 25: ...8 C f Select CAL on the display and go forward as mentioned under point 1 7 see above The actual bath temperature switches from 45 C to 44 8 C and the unit starts to heat up until the actual bath tem...

Page 26: ...hing heating is switched off on both poles pump is switched off by the electronics Rectify the cause of the fault Wait until the bath temperature has cooled down below the switch off point or set the...

Page 27: ...ome of the bath liquid into a suitable container Step 1 2 must follow Bath temperature during this test not below 0 C or higher than 50 C otherwise danger of burn injuries If there is any irregularity...

Page 28: ...peated pull out the mains plug and try whether the motor can be rotated by the fan blade inserting a screwdriver into the ventilation opening at the back of the unit Error code 0 255 microprocessor er...

Page 29: ...ding to EN 60601 1 or IEC 601 1 7 2 Other safety notes Connect the unit to a grounded mains power socket Parts of the bath cover may reach surface temperatures above 70 C when operating at higher temp...

Page 30: ...the cooling water has only to be used for operating temperatures below 100 C At higher temperatures danger of hot vapour to be produced Always pull out the mains plug before cleaning maintenance or mo...

Page 31: ...ser In case of doubt please contact the manufacturer 8 2 Maintenance and repair Before any maintenance and repair work pull out the mains plug Repair on the control unit must only be carried out by pr...

Page 32: ...pply of incorrect items We shall always be happy to deal with queries and to receive suggestions and criticism LAUDA DR R WOBSER GMBH CO KG P O Box 1251 97912 Lauda K nigshofen GERMANY Phone 49 0 9343...

Page 33: ...h water cooling C 20 to 120 Operating temperature range C 20 to 120 Heater power 230 V 50 60 Hz 115 V 60 Hz 100 V 50 60 Hz 1 5 1 3 1 0 Pump type pressure pump with choice of 5 output steps Max dischar...

Page 34: ...12 T E 115 T E 120 T Operating temperature range C 23 to 100 with water cooling C 20 to 100 Operating temperature range C 20 to 100 Heater power 230 V 50 60 Hz 115 V 60 Hz 100 V 50 60 Hz kW 1 5 1 3 1...

Page 35: ...2 4 6 8 10 12 14 16 18 20 l min bar step 5 step 4 step 3 step 2 step 1 Bath Circulation thermostats measured with water 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 0 2 4 6 8 10 12 14 16 18 l min bar s...

Page 36: ...stainless steel 150 2 5 to 3 5 135x240x150 LCZ 0620 011 deep drawn stainless steel 150 9 to 12 300x329x150 LCZ 0621 019 deep drawn stainless steel 150 12 to 18 300x505x150 LCZ 0622 025 deep drawn sta...

Page 37: ...119 E 125 LCZ 0634 Cover plate E 115 T LSZ 0115 Rising platform 8 steps E 103 LCZ 0645 Rising platform 8 steps E 1206 T LCZ 0648 Rising platform 8 steps E 112 T E 111 E 120 T E 119 E 125 LCZ 0635 Thr...

Page 38: ...Circuit diagram 05 08 99 YACD0059 31 11 Circuit diagram Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 39: ...inal 12pol EQF 079 EQF 079 EQF 079 X 23 Line up terminal 2pol EZK 063 115V 60Hz 100V 50 60Hz at serial no X01 E 1xx E 2xx E 3xx A 1 Printed circuit board Mains UL 499 UL 499 UL 499 A 2 Printed circuit...

Page 40: ...e Serien Nr Serial no No de s rie mit folgendem Medium betrieben wurde was used with the below mentioned media a t utilis avec le liquide suivant Dar ber hinaus best tigen wir da das oben aufgef hrte...