background image

                                                               

MG-300 

EN-2 

3 Features 

 

Switch between the display of micro-Tesla and 
mini-Gauss is available. 

 

Data hold (HOLD)

maximum (MAX) Hold function. 

 

Range display(20,200,2000). 

 

Low battery detector “

”. 

 

Over load display “OL”. 

 

4 Identifying Parts 

1. Sensor  position. 
2. LCD                         
3. Power  on/off. 
4. maximum hold button 
5. Data hole button 
6. mG unit select button     
7. µT unit select button 
8. Range select button 
9. Battery  cover.

 

Summary of Contents for MG-300

Page 1: ...LF Magnetic Field Meter MG 300 HB4MG3000000...

Page 2: ......

Page 3: ...Table of Contents 1 Introduction 1 2 Application 1 3 Features 2 4 Identifying Parts 2 5 Measurement Procedures 3 6 Specifications 5 7 Battery replacement 6 8 Safety Precaution 6 9 End of life 7...

Page 4: ...s a form of energy similar to light and heat that can be transmitted either by radiation in the air or by an electric conductor It is suggested that rearrangements should be made in families and work...

Page 5: ...Data hold HOLD maximum MAX Hold function Range display 20 200 2000 Low battery detector Over load display OL 4 Identifying Parts 1 Sensor position 2 LCD 3 Power on off 4 maximum hold button 5 Data hol...

Page 6: ...on the left highest position indicates there is an overload on the reading Please press to select a higher range for measurement again Due to the environmental magnetic field factors this magnetic fi...

Page 7: ...MG 300 EN 4 Figure 1 indicate the correct measurement direction of the electromagnetic wave Figure 2 3 4 5 and 6 indicate the incorrect measurement direction of the electromagnetic wave...

Page 8: ...Single Axis Accuracy 2 5 6dgt at 50Hz 60Hz Over load LCD display OL Sample rate 2 5 times per second Battery 9V NEDA 1604 IEC 6F22 or JIS 006P Battery life Approximate 100 hours Operating temperature...

Page 9: ...Precaution For cleaning the instrument use a soft dry cloth Never use a wet cloth solvents or water etc Operation Altitude Up to 2000M Operating Environment Indoors use This instrument has been design...

Page 10: ...MG 300 EN 7 9 End of life Caution this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal...

Page 11: ......

Page 12: ...EMR Shielding Solutions Inc 399 Four Valley Drive Unit 13 Vaughan Ontario L4K 5Y7 Canada E mail info emrshieldingsolutions com www emrshieldingsolutions com...

Reviews: