4
DRYWALL
THERMOSTAT
FACEPLATE
MUD-RING
BACK BOX
For retro-fit installations where the drywall is already in place, you
will need to mud over the mud-ring. In either case, the mud-ring
and backbox must be installed behind the drywall.
NOTE:
All cables and connections must be carried out by a qualified electrician and must
conform to the local electrical code. Conduits are only required where it is mandated by state
or provincial code. Please refer to local electrical code for compliant applications.
L1-LOAD-L2
LINE
L1
L2
1
2
3
EXT
SENSOR
(NO POLARITY)
RED
LOAD
BLACK
LINE
BLACK
LINE
RED
BARE COPPER
(ground)
FLOOR
SENSOR
HEATER
15A MAX.
Do not use where exposed to water
Ne pas installer à proximité d’une source d’eau
EXT
SENSOR
(NO POLARITY)
1
2 3
LINE
L1
L2
Caution: High Voltage
Disconnect power supply
before servicing.
AVERTISSEMENT:
HAUTE TENSION
INSTALLATION
ELECTRICAL WIRING
STRATA_HEAT™ Programmable Thermostat
Easy Setup Guide