background image

LATICRETE

      DS 606.3E                    18/1/07                    2/2

6.3

Floor Temperature Limits (AF mode only)

NOTE: To avoid damaging your floor, follow your floor supplier’s rec-
ommendations regarding floor temperature limits.

The minimum and maximum floor temperature limits are 41 °F (5 °C)
and 82 °F (28 °C) by default. To modify these limits, proceed as fol-
lows:

n

Switch the thermostat to Standby.

o

Press and hold the 

 button.

p

Switch the thermostat back to On.

q

Release the 

 button when the minimum temperature 

limit (

FL:LO

) appears.

r

Set the minimum temperature limit using the 

 

buttons.

s

Press the 

 button to display the maximum 

temperature limit (

FL:HI

).

t

Set the maximum temperature limit using the 

 buttons.

u

Press 

Mode/Ret

 to exit.

The thermostat has 3 modes of operation.

7.1

 Automatic Mode

The thermostat follows the programmed schedule. To place the ther-

mostat in this mode, press 

Mode/Ret

 until   is displayed. The data of

the current schedule period are also displayed.

Temporary Bypass

If you modify the setpoint temperature (by pressing the 

 or 

button) when the thermostat is in automatic mode, the new tempera-

ture will be used until the beginning of the next period.   flashes dur-
ing the bypass. You can cancel the bypass by pressing 

Mode/Ret

.

Programmed Schedule

The schedule consists of 4 periods per day which represents a typi-
cal week day. You can program the thermostat to skip the periods
that do not apply to your situation. For example, you can skip periods
2 and 3 for the weekend.

The Comfort (

) temperature is used in periods 1 and 3 and the

Economy ( ) temperature is used in periods 2 and 4. For example,
when the period changes from 1 to 2, the setpoint automatically

changes from Comfort (

) temperature to Economy ( ) temperature.

You can have a different program for each day of the week; i.e., each
period can start at different time for each day of the week. The
thermostat has been programmed with the following schedule.

To modify the schedule:

n

Press 

Pgm

 to access the programming mode. Period 1 is 

selected.

o

Press 

Day

 to select the day to program (hold for 3 seconds to 

select the entire week).

p

Press 

Hour

 and 

Min

 to set the start time of the selected period, 

or press 

Clear

 if you want to skip the period (--:-- is displayed).

q

Press 

Pgm

 to select another period, or press 

Day

 to select 

another day. Then repeat step 3.

r

Press 

Mode/Ret

 to exit the programming mode.

NOTE: 

If no button is pressed for 60 seconds, the thermostat will

automatically exit the programming mode. 

7.2

 Manual Mode

The programmed schedule is not used. The temperature must be set
manually. To place the thermostat in this mode:

n

Press 

Mode/Ret

 until   is displayed.

o

Set the temperature using the 

 or   button.

7.3

 Vacation Mode

In this mode, the thermostat is set to Vacation temperature. There
are two ways to place the thermostat in Vacation mode:

By pressing the 

 button on the thermostat. When the Vacation

mode is activated using the   button, the 

 icon appears on the

screen without flashing.

From any remote control device equipped with a dry contact.
When the contact closes, the Vacation mode is activated and the

 icon flashes on the screen. All buttons on the thermostat are

locked. When the contact opens, the thermostat returns to the
preceding mode.

NOTE: When the Vacation mode is activated using a remote
control device, it can only be deactivated using the device

.

The measured temperature is below the thermostat’s display
range. Heating is activated.

The measured temperature is above the thermostat’s display
range. Heating is deactivated.

Verify the thermostat and sensor connections.

:

Power supply

: Refer to the power base’s installation guide.

Display range

: 32 °F to 158 °F (0 °C to 70 °C)

Ambient setpoint range (A/AF modes)

: 40 °F - 86 °F (5 °C to 30 °C)

Floor setpoint range (F mode)

: 40 °F - 104 °F (5 °C to 40 °C)

Floor limit range (AF mode)

: 40 °F - 104 °F (5 °C to 40 °C)

Display resolution

: 1 °F (0.5 °C)

Operating temperature

: 32 °F to 120 °F (0 °C to 50 °C)

Storage temperature

: -4 °F to 120 °F (-20 °C to 50 °C)

Heating cycle length

: Refer to the power base’s installation guide

Data backup

: In the event of a power failure, most settings are saved. Only

the time must be re-adjusted if the power failure lasts more than 6 hours. The
thermostat will return to the mode that was active prior to the power failure.

Subject to the conditions and limitations stated below, LATICRETE INTERNATIONAL,
INC. (“LATICRETE”) warrants this product to be free from manufacturing defects for a
period of one (1) year from the date of purchase of the product. As a condition of this lim-
ited warranty, you may be required, at the option of LATICRETE, to provide proof of prod-
uct purchase and use. 
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY,
EXPRESS OR IMPLIED. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES BASED ON SAMPLES OR ORAL STATEMENTS, WHICH
EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IMPLIED WARRAN-
TIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE ARE
EXCLUDED.
The sole and exclusive remedy for a breach of this limited warranty is replacement of the
LATICRETE product that is proven defective. In the event this sole and exclusive remedy
fails of its essential purpose, the liability of LATICRETE is limited to the return of the orig-
inal purchase price. 
LATICRETE is not responsible for workmanship not in accordance with LATICRETE
instructions and industry standard guidelines. Cracking due to structural movement,
excessive deflection or other failure in the substrate is also not covered.
LATICRETE IS NOT LIABLE FOR ANY INCIDENTAL DAMAGES OR CONSEQUEN-
TIAL DAMAGES, INCLUDING LOSSES DUE TO DELAYS, INCURRED BY THE PUR-
CHASER OR ANY OTHER PARTY.
The LATICRETE Programmable Thermostat is a component of the LATICRETE Lifetime
Residential Warranty and the LATICRETE 10 Year System Warranty.  See DS700.12 and
DS230.12 for complete details.

For any questions regarding LATICRETE product installation or operation, contact
us at:

Phone

:  800.243.4788 ext. 235

Fax

:  203.393.1296

Email

:  [email protected]

Monday to Friday, 8:00 AM to 5:00 PM EST

For more information on our products, visit us at:

www.laticrete.com

t

Modes of Operation

7.

Period

Description

Associated temperature setting

Wake-up

Away from home

Return home

Sleep

Period

Setting

MO

TU

WE

TH

FR

SA

SU

6:00 
a.m.

6:00 
a.m.

6:00 
a.m.

6:00 
a.m.

6:00 
a.m.

6:00 
a.m.

6:00 
a.m.

8:30 
a.m.

8:30 
a.m.

8:30 
a.m.

8:30 
a.m.

8:30 
a.m.

--:--

--:--

5:00 
p.m.

5:00 
p.m.

5:00 
p.m.

5:00 
p.m.

5:00 
p.m.

--:--

--:--

11:00 

p.m.

11:00 

p.m.

11:00 

p.m.

11:00 

p.m.

11:00 

p.m.

11:00 

p.m.

11:00 

p.m.

u

Error Messages

8.

v

Technical Specifications

9.

;

Warranty

10.

Customer Assistance

11.

Reviews: