Operational Description

 

 
To use the Remote Bell Ringer, the Operator will first select, via the 
Rotary Switch, which of the Bell Circuits are to be made active. 
Selected Circuits that are not configured as Bell Circuits in the Master 
Controller will be ignored 

y

 

The ‘OFF’ position may be used to de-activate all Bell Circuits 

y

 

Positions ‘1’ to ‘8’ may be used to select a single Bell Circuit to be 
made ‘Active’ 

y

 

The ‘ALL’ position may be used to activate all circuits configured 
as Bell Circuits. 

After setting the selected position of the Rotary Switch, the Operator 
should press the ‘ENTER SELECTION’ Push-Button. This will ‘wake-
up’ the Microprocessor (indicated by a brief ‘flash’ of the indicators) 
which will, in turn, read the Switches and transmit the appropriate 
Command to the Master. It will wait for a reply from the Master, which 
will indicate the Bell Circuits which are now Active, and display that 
information on Lighting Indicators as confirmation to the Operator that 
the Command has been accepted and executed by the Master. The lit 
Indicators will remain active for 2 seconds after the button is released, 
after which the unit will go back to ‘sleep mode’, to conserve power. 

Summary of Contents for LTR-RBR

Page 1: ...LTR RBR REMOTE BELL RINGER Installation User s Guide...

Page 2: ...ntial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commun...

Page 3: ...PERATION INSTALLATION AND MAINTENANCE MANUAL REMOTE BELL RINGER LATHEM TIME CORP Doc USG0027A LTR8 512 and MasterLink are Registered Trademarks of Lathem Time Corp Atlanta GA USA 2003 LATHEM TIME CORP...

Page 4: ...5PM for a duration of 7 seconds While eight Schedules may be stored in the Master the User may select which of the eight may be Active As time advances each minute the day and time are automatically c...

Page 5: ...a low power MicroProcessor a method of selecting the Address of the Master to be remotely controlled and a 4 screw Terminal Block for Installer Interconnect Two screws of the Terminal Block are for at...

Page 6: ...dress Selector switch jumpers to match the Master s Programmed Address default Code 65 and attach the Communication Cable wire pair with proper polarity and the low voltage Power Pair to the Terminal...

Page 7: ......

Page 8: ...its After setting the selected position of the Rotary Switch the Operator should press the ENTER SELECTION Push Button This will wake up the Microprocessor indicated by a brief flash of the indicators...

Page 9: ...Master Control Remote Bell Ringer...

Page 10: ......

Page 11: ...This warranty does not apply to any product which has been subject to abuse neglect or accident or which has had the serial number altered or removed or which has been connected installed adjusted or...

Page 12: ...ith all faults In no event will Lathem be liable for any direct indirect special incidental or consequential damages arising out of or in connection with the delivery use or inability to use or perfor...

Page 13: ...Lathem Time 200 Selig Drive SW Atlanta GA 30336 404 691 0405 www lathem com Copyright 2003 Lathem Time Corporation All rights reserved...

Reviews: