Lathem LTR-RBR Installation & User Manual Download Page 5

 

 

select and activate one (1) of the eight (8) possible Bell Circuits or all 
Bell Circuits (those circuits not defined as Clock Control Circuits) in 
the Master Controller. The selection made will execute when the push 
button on the Remote Bell Ringer’s Panel is pressed, and those circuits 
will remain activated until the button is released. 

The Assembly of the Remote Bell Ringer consists of an Electronic 
Circuit suspended beneath a cover plate for a double-gang switch-type 
electrical box (not supplied with the product). The Circuit includes a 
low-power MicroProcessor, a method of selecting the ‘Address’ of the 
Master to be remotely controlled,  and a 4-screw Terminal Block for 
Installer Interconnect. Two screws of the Terminal Block are for 
attachment of the Twisted-Pair (Cat-3 typical) low-voltage Network 
Communications Cable to the Master’s RS-485 Port. The other two 
screws are to be used for supplying 9-24V AC/DC as continuous power 
source to the unit. 

On the face of the cover plate are a 9-position Rotary Switch (to select 
the Circuits to be made ‘Active’), a Push Button to send the Command 
to the Master, and an array of lighting Status Indicators by which the 
Operator can receive confirmation from the Master that the Manual 
Bells Command has been accepted and acted upon. 

Summary of Contents for LTR-RBR

Page 1: ...LTR RBR REMOTE BELL RINGER Installation User s Guide...

Page 2: ...ntial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commun...

Page 3: ...PERATION INSTALLATION AND MAINTENANCE MANUAL REMOTE BELL RINGER LATHEM TIME CORP Doc USG0027A LTR8 512 and MasterLink are Registered Trademarks of Lathem Time Corp Atlanta GA USA 2003 LATHEM TIME CORP...

Page 4: ...5PM for a duration of 7 seconds While eight Schedules may be stored in the Master the User may select which of the eight may be Active As time advances each minute the day and time are automatically c...

Page 5: ...a low power MicroProcessor a method of selecting the Address of the Master to be remotely controlled and a 4 screw Terminal Block for Installer Interconnect Two screws of the Terminal Block are for at...

Page 6: ...dress Selector switch jumpers to match the Master s Programmed Address default Code 65 and attach the Communication Cable wire pair with proper polarity and the low voltage Power Pair to the Terminal...

Page 7: ......

Page 8: ...its After setting the selected position of the Rotary Switch the Operator should press the ENTER SELECTION Push Button This will wake up the Microprocessor indicated by a brief flash of the indicators...

Page 9: ...Master Control Remote Bell Ringer...

Page 10: ......

Page 11: ...This warranty does not apply to any product which has been subject to abuse neglect or accident or which has had the serial number altered or removed or which has been connected installed adjusted or...

Page 12: ...ith all faults In no event will Lathem be liable for any direct indirect special incidental or consequential damages arising out of or in connection with the delivery use or inability to use or perfor...

Page 13: ...Lathem Time 200 Selig Drive SW Atlanta GA 30336 404 691 0405 www lathem com Copyright 2003 Lathem Time Corporation All rights reserved...