Welcome to the LTR-RBR (Remote Bell Ringer)

 

 

Lathem’s LTR8-512 Master Controller for Clocks and Bells is capable 
of storing up to eight (8) Schedules for Bells and Control Zones, each 
of which may contain up to sixty-four (64) multi-function ‘Events’. An 
‘Event’ may be defined by a very simple instruction, such as “Ring the 
Bell on Circuit #4 for 3-seconds every day at 3:00PM”, or it may 
contain a more complicated definition, as, “On Mondays, Wednesdays, 
Fridays and Holidays, Activate Circuits #2, #3 and #4 at 2:45PM for a 
duration of 7-seconds.” While eight Schedules may be stored in the 
Master, the User may select which of the eight may be ‘Active’. As 
time advances each minute, the day and time are automatically 
compared against the Events stored in the Schedules which have been 
selected as ‘Active’. If a match is found, the programmed Event is 
executed. The Master Controller also provides the capability for 
Manually Activated Bells, through the use of KeyPad Function 
[#][3}[#], which allows the user to select one or more of the Bell 
Circuits to be activated by subsequent press of the [#] key. 

The “Remote Bell Ringer”, an accessory for the LTR8-512 Master 
Controller (Firmware v4.08 and above, only), allows an Operator to 

Summary of Contents for LTR-RBR

Page 1: ...LTR RBR REMOTE BELL RINGER Installation User s Guide...

Page 2: ...ntial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commun...

Page 3: ...PERATION INSTALLATION AND MAINTENANCE MANUAL REMOTE BELL RINGER LATHEM TIME CORP Doc USG0027A LTR8 512 and MasterLink are Registered Trademarks of Lathem Time Corp Atlanta GA USA 2003 LATHEM TIME CORP...

Page 4: ...5PM for a duration of 7 seconds While eight Schedules may be stored in the Master the User may select which of the eight may be Active As time advances each minute the day and time are automatically c...

Page 5: ...a low power MicroProcessor a method of selecting the Address of the Master to be remotely controlled and a 4 screw Terminal Block for Installer Interconnect Two screws of the Terminal Block are for at...

Page 6: ...dress Selector switch jumpers to match the Master s Programmed Address default Code 65 and attach the Communication Cable wire pair with proper polarity and the low voltage Power Pair to the Terminal...

Page 7: ......

Page 8: ...its After setting the selected position of the Rotary Switch the Operator should press the ENTER SELECTION Push Button This will wake up the Microprocessor indicated by a brief flash of the indicators...

Page 9: ...Master Control Remote Bell Ringer...

Page 10: ......

Page 11: ...This warranty does not apply to any product which has been subject to abuse neglect or accident or which has had the serial number altered or removed or which has been connected installed adjusted or...

Page 12: ...ith all faults In no event will Lathem be liable for any direct indirect special incidental or consequential damages arising out of or in connection with the delivery use or inability to use or perfor...

Page 13: ...Lathem Time 200 Selig Drive SW Atlanta GA 30336 404 691 0405 www lathem com Copyright 2003 Lathem Time Corporation All rights reserved...

Reviews: