c) Mount the Pivot Mount Assembly to the back wall of the automatic safety cover housing with a 1" clearance
between the top of the front wall of the automatic safety cover housing and the underside of the Pivot Mount
Assembly . The Pivot Mount Assembly must be level to function properly .
d) Adjust the Pivot Mount Assembly extension to place the pivot point near the front of the lid support brackets as
shown in the diagram below .
e) Install the Pump Head and Extension Tubing pivot into the Pivot Mount Assembly by removing the screws on the
front of the assembly and inserting the pivot in between the pivot brackets as shown in the diagram below . Close
the pivot brackets and reinstall the screws .
6 AutoDrain Pump Usage and Installation Manual
L0016-15 AutoDrain Installation Man .indd 7