![Latham COVERSTAR AutoDrain Usage And Installation Manual Download Page 5](http://html1.mh-extra.com/html/latham/coverstar-autodrain/coverstar-autodrain_usage-and-installation-manual_3805111005.webp)
4 AutoDrain Pump Usage and Installation Manual
Step 2: Assemble the Pump Head and Extension Tubing
a) Uncoil the wire that is attached to the PUMP HEAD. Uncoil the 5/8" HOSE. Attach the 5/8" HOSE to the PUMP HEAD
at the connection fitting .
b) Feed the wire and the hose through
the following parts in this order:
• Pump Head to Union Ext Tube
• Union, Union to Hinge Ext Tube
• Pivot Assembly
c) Secure the tube joints using the 10-32 X 1/4" screws that are provided.
Secure the hinge connection using the 10-32 X 3/8" screws that are provided.
L0016-15 AutoDrain Installation Man .indd 5
1/30/15 8:40 AM